Precor QUEENAX PF175 2D Installation/Assembly Manual
Precor QUEENAX PF175 2D Installation/Assembly Manual

Precor QUEENAX PF175 2D Installation/Assembly Manual

Wall solution

Advertisement

Installation Assembly Guide
QUEENAX™ PF175 2D
WALL SOLUTION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QUEENAX PF175 2D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Precor QUEENAX PF175 2D

  • Page 1 Installation Assembly Guide QUEENAX™ PF175 2D WALL SOLUTION...
  • Page 2: Table Of Contents

    Contents Introduction Additional Documentation Contact Information General Information Tools Safety Equipment Orientation Convention Equipment Part and Option Identification Torque Specifications Cleaning Getting Started Baseline installation procedure Installation and assembly requirements Receiving Parts Assembly and Installation Tips Unpacking boxes Fastener Tips Assembly and Installation Introduction Procedure...
  • Page 3 Horizontal Bag Shelf Optional Assembly Universal Rack Element Floor Anchoring Requirements Floor material requirements Anchor bolt requirements Torque specification Approved anchor bolt types Anchor bolt installation Summary Appendix A : Edition Information Edition Copyright Trademarks Safety Instruction Safety Notices...
  • Page 4: Introduction

    Solution storage unit. Follow the assembly instructions in the order given to correctly and efficiently assemble and install the unit. If you are not a Precor Queenax certified servicer, you must not attempt to install and assemble this Precor product. Call your dealer for information.
  • Page 5: Additional Documentation

    Additional Documentation You can also view the install assembly guide online at : Online Service Manual Contact Information Contact Precor Queenax installation coordinator or e-mail at queenaxinstalls@precor.com with any issues prior to or during installation. See Also "General Information" on page 3 "Getting Started"...
  • Page 6: General Information

    2 General Information Tools General Information This section provides general information that will help you to use this guide to assemble and install the PF175 2D Wall Solution storage unit including the required tools, specifications, parts iden- tification, unit orientation, cleaning, etc. Tools The following tools are required to assemble Queenax products: Note: One set of power tools per installer is recommended.
  • Page 7: Safety Equipment

    2 General Information Safety Equipment 1 short set and 1 long set with ball end 3/8” metric hex sockets (13 mm, 17 mm, and comm ½” universal joint ½” to 3/8” socket adapter ½” short and long extensions Vacuum cleaner Note: One set of power tools per installer is recommended.
  • Page 8: Equipment Part And Option Identification

    2 General Information Equipment Part and Option Identification Equipment Part and Option Identification...
  • Page 9: Torque Specifications

    2 General Information Torque Specifications (missing or bad snippet) Torque Specifications This table provides a summary of system component specifications. System Component Specification M10 Bolt torque [[[Undefined variable Specifications.QNX- M10Bolt]]] M12 bolt torque [[[Undefined variable Specifications.QNX- M12Bolt]]] M14 bolt torque [[[Undefined variable Specifications.QNX- M14Bolts]]]...
  • Page 10: Cleaning

    2 General Information Cleaning System Component Specification Anchor bolt torque [[[Undefined variable Specifications.QNX- AnchorBolt]]] Note: 1) see "Floor Anchoring Requirements" on page 1 Cleaning 1. Wipe down equipment with recommended cleaning solution. General: 1 oz. mild soap to 30 oz. water. . (missing or bad snippet) 2.
  • Page 11: Getting Started

    With experience you may find more efficient methods of installation. Always verify changes and/or alternate methods of assembly and installing the unit with the Precor Queenax installation coordinator. IMPORTANT: Always verify any procedural changes or alternative methods to this installation procedure with the Precor Queenax installation coordinator.
  • Page 12: Assembly And Installation Tips

    3 Getting Started Assembly and Installation Tips Assembly and Installation Tips Unpacking boxes Place part and assembly boxes as close to the installation location as possible. Keep all individual part and assembly fastener hardware together. Do not intermix or use fastener hardware for other than the intended part installation.
  • Page 13: Assembly And Installation

    This assembly installation procedure provides a baseline procedure that will reliable install the unit. With experience you may find more efficient methods of installation. Always verify changes and/or alternate methods of assembly and installing the unit with the Precor Queenax product installation department.
  • Page 14 4 Assembly and Installation Procedure and torque to [[[Undefined variable Specifications.QNX-M12Bolt]]]. Description Q2017PFY-101 TOWER TERMINAL 10,PF YELLOW CWHMCN012-030 SCREW,HHC,M12X1.75X30,STL,CZ CWWNCN012-025 WASHER,FLAT,STEEL,METRIC,M12 X 36 OD X 2.5T, CZ CWWNCN012-025 WASHER,FLAT,STEEL,METRIC,M12 X 36 OD X 2.5T, CZ CWWBWCN012- WASHER, SPLIT, M12 X 2.3MM THICK, CZ CWKARCN012-010 NUT,PLAIN,HEX,M12,STL,CZ, DIN 934 Q2275PFY-101...
  • Page 15: Anchor The Towers To The Floor

    4 Assembly and Installation Procedure Description Q2275PFY-101 ASSY,BEAM,SECTION,250 S 2.0,PF YELLOW Q2052QMS-101 FLOOR FIXING 25, SILVER CWKFCN010-008 NUT,LOCK,FULL,M10,NYLON INSERT,STL,CZ CWWNCN010-025 WASHER,FLAT,STEEL,METRIC,M10 X 40 OD X 2.5T, CWWKCN010-019 WASHER, FLAT, STEEL, METRIC, M10 X 1.9MM THICK, CZ CWTECN010-030 SCREW,BHC,M10X1.5X30,CZ Note: Part qty on a per unit basis. Anchor the towers to the floor 4.
  • Page 16 4 Assembly and Installation Procedure 6. Verify that the customer approves the unit location. Always receive customer approval before doing any floor covering alterations or drilling of the anchor fastener holes. IMPORTANT: Do not make any alterations to the flooring or drill any anchor bolt holes before verifying location with the customer.
  • Page 17 Procedure IMPORTANT: Before anchor bolt installation read the Floor Anchoring Requirements topic (see "Floor Anchoring Requirements" on page 27). Only use the Precor approved anchor bolt types (see "Approved anchor bolt types" on page 27) and adhere to the anchor bolt install- ation depth and position instructions (see "Anchor bolt installation Summary"...
  • Page 18: Install The Tower Placards

    4 Assembly and Installation Procedure WARNING: Review the site survey prior to ANY drilling and make sure that there are no conditions or obstacles (such as electrical conduit, post-tension rebar, etc.) that could cause personal or facility damage while drilling. 10. Mount the left and right towers onto the anchor bolts and secure using the anchor bolt washer and nut.
  • Page 19 4 Assembly and Installation Procedure...
  • Page 20: Anchor The Floor Fixings To The Floor

    4 Assembly and Installation Procedure Description Q40022-101 WALL BAR 125,BOX OF 4 Q2275PFY-101 TOWER - LEFT Q2275PFY-101 TOWER - RIGHT CWKFCN010-008 NUT,LOCK,FULL,M10,NYLON INSERT,STL,CZ CWWNCN010-025 WASHER,FLAT,STEEL,METRIC,M10 X 40 OD X 2.5T, CWWKCN010-019 WASHER, FLAT, STEEL, METRIC, M10 X 1.9MM THICK, CZ CWTECN010-030 SCREW,BHC,M10X1.5X30,CZ Note: Part qty on a per unit basis.
  • Page 21 4 Assembly and Installation Procedure Description Q40052-101 MINI WALL BAR CWWKCN010-019 WASHER, FLAT, STEEL, METRIC, M10 X 1.9MM THICK, CZ CWWBWCN010-020 WASHER, SPLIT LOCK, M10 X 2.0MM THICK, CZ CWTECN010-035 SCREW,BHC,M10X1.5X35,CZ Note: Part qty on a per unit basis. b. Drill the three floor fixing anchor bolt holes per the floor fixing 25 bolt pattern diagram shown below.
  • Page 22 4 Assembly and Installation Procedure c. Install the three anchor bolts and secure using the washer and nut. Fully tighten each floor fixing anchor bolt and torque to specification [[[Undefined variable Spe- cifications.QNX-AnchorBolt]]]. d. Fully tighten the four tower anchor bolt and torque to specification [[[Undefined variable Specifications.QNX-AnchorBolt]]].
  • Page 23: Install Remaining Panels

    4 Assembly and Installation Procedure Install remaining panels 14. Install the four tower panel covers on the left and right towers. Secure using either the panel clips or the fixing carter bars with elastic band. Description Q40035-125 BEAM PANEL COVER125CM Note: Part qty on a per unit basis.
  • Page 24: Install Placards, Labels, And Decals

    4 Assembly and Installation Procedure a. Assemble and Install the Horizontal VIPR & Roller Shelf optional. see "Horizontal VIPR & Roller Shelf Optional Assembly " on the next page. b. Assemble and Install the Horizontal Bag Shelf optional, see "Horizontal Bag Shelf Optional Assembly"...
  • Page 25: Horizontal Vipr & Roller Shelf Optional Assembly

    4 Assembly and Installation Horizontal VIPR & Roller Shelf Optional Assembly Horizontal VIPR & Roller Shelf Optional Assembly Use the unit rendering to determine the number and installation location for the Horizontal VIPR & Roller Shelf optional installation. 1. Attach the VIPR & roller elements onto the horizontal rack using the M10 hex key bolt, and flat washer fasteners.
  • Page 26: Horizontal Bag Shelf Optional Assembly

    4 Assembly and Installation Horizontal Bag Shelf Optional Assembly Description CWCNCN010-030 SCREW,FHC,M10X1.5X30,STL,CZ Note: Part qty on a per unit basis. 2. Install the assembled VIPR & roller shelf onto the unit. Use the rendering to determine install- ation location. See Also "Install the Unit Optionals"...
  • Page 27 4 Assembly and Installation Horizontal Bag Shelf Optional Assembly Description Q40136-104 TUBE,ROUND,STL,50MM OD X 2MM THK X 500 MM Q2082 HORIZONTAL REMOVABLE RACK CWTEKN010-025 SCREW,BHC,M10X1.5X25,STL,BZ CWWKKN010-020 WASHER, FLAT, STEEL, METRIC, M10 X 2 MM THICK, BZ Q40385-101 FLANGE,2 HOLED,BAG RACK Q40042-101 SPACER,TAPPED,M10-1.5 Note: Part qty on a per unit basis.
  • Page 28: Universal Rack Element

    4 Assembly and Installation Universal Rack Element Universal Rack Element Use the unit rendering to determine the number and installation location for the Universal Rack Ele- ment optional installation. 1. Attach the horizontal removable rack onto the universal rack element. Secure using the screw, washer, spacer, washer, and hex key screw.
  • Page 29 4 Assembly and Installation Universal Rack Element Description Q2085 Universal Rack Element Q2082 Horizontal Removable Rack CWTEKN010-070 SCREW,BHC,M10X1.5X70,STL,BZ CWWKKN010-020 WASHER, FLAT, STEEL, METRIC, M10 X 2 MM THICK, BZ Q40739-101 SPACER SLEEVE, FOR M10 BOLT Q40041-101 WASHER,STEEL,CUSTOM METRIC,59 OD X 11 ID X 5 THK CWKFKN010-008 NUT,LOCK,FULL,M10,NYLON INSERT,STL,BLK...
  • Page 30: Floor Anchoring Requirements

    Floor Anchoring Requirements Use this information to learn how to anchor (attach) the unit to the facility flooring. The installation requirements described in this section must be adhered to confirm a Precor approved installation. Floor material requirements Concrete is the only permitted and approved floor material type.
  • Page 31: Anchor Bolt Installation Summary

    4 Assembly and Installation Anchor bolt installation Summary Anchor bolt installation Summary The minimum anchor penetration depth requirement is determined by the expansion bolt type. Make sure that the concrete floor depth can support the required anchor bolt depth: Expansion anchors must have minimum 3-1/4” (8 mm) embedment Chemical anchors must have minimum 4”...
  • Page 32 4 Assembly and Installation Anchor bolt installation Summary Anchor Type Parameter Specification Expansion Concrete Depth [[[Undefined variable Specifications.QNX-Expan- Anchor sionAnchorDepth]]] Expansion Anchor Size [[[Undefined variable Specifications.QNX- Anchor ExpAnchorLength]]] Expansion Minimum embed- [[[Undefined variable Specifications.QNX- Anchor ment Depth ExpEmbedment]]] Chemical Anchor Concrete Depth [[[Undefined variable Specifications.QNX-Chem- icalAnchorDepth]]]...
  • Page 33: Appendix A : Edition Information

    No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Precor Incorporated as governed by United States and international copyright laws. Precor Incorporated 20031 142nd Ave.
  • Page 34 A Edition Information ated conditions are fully understood.

Table of Contents