1 8 | Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Outdoor Unit

6 Error Codes

Safety
WARNING: ELECTRICAL HAZARD
Electricity power is still kept in capacitors even if the power
supply is shut off. Do not forget to discharge the electricity
power in capacitor before servicing the system.
Electrolytic Capacitors
(HIGH VOLTAGE! CAUTION!)
Figure 11

6.1 Error Codes - Wall Mounted Indoor Unit

Number
Cause
1
Indoor unit EEPROM error
2
Communication error between indoor unit and outdoor units
3
Indoor fan speed error
4
Indoor Return air temperature sensor error
5
Indoor coil temperature sensor error
6
Low refrigerant
7
Outdoor current overload sensed
8
Outdoor ambient temperature sensor error
9
Outdoor coil temperature sensor error
10
Compressor discharge temperature sensor error
11
Outdoor unit EEPROM error
12
Outdoor unit fan speed error
13
Indoor coil outlet temperature sensor error
14
Inverter module IPM error
15
High or Low voltage protection
16
Outdoor unit low temperature lockout
17
Compressor drive error
18
Mode con ict
Table 12
If you see an error code not displayed in Table 12, contact the
manufacturer as the error displayed is for development purpose only.
Data subject to change
For other models, please connect discharge resistance (approx.100 40W)
between +, - terminals of the electrolytic capacitor on the opposite side of the
outdoor PCB. A screwdriver will also work as a resistive element.
For reference the most common error codes are E1, P0, and P3.
RUN Indicator Flashes
1
2
4
5
6
7
1
2
3
4
5
6
7
1
2
4
5
6
Service Manual
TIMER Indicator
Error Code
OFF
E0
OFF
E1
OFF
E3
OFF
E4
OFF
E5
OFF
EC
LIT
F0
LIT
F1
LIT
F2
LIT
F3
LIT
F4
LIT
F5
LIT
F6
FLASH
P0
FLASH
P1
FLASH
P3
FLASH
P4
FLASH
P5
04.2020 | Bosch Thermotechnology Corp.