Multi Zone Outdoor Unit Error Codes - Bosch Climate 5000 Series Service Manual

Ductless air conditioner / heat pump multi zone outdoor units
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

Service Manual

8.1 Multi Zone Outdoor Unit Error Codes

NOTICE
If below error codes appear, please turn off the system and
contact an Authorized Service Provider.
ODU Display
Possible Causes
E0
Outdoor unit EEPROM parameter error
E2
Communication malfunction between indoor and outdoor units
E3
Communication malfunction between IPM board and outdoor main control board
Outdoor temperature sensor (coil sensor T3, ambient sensor T4, Compressor
E4
discharge sensor T5, indoor coil outlet pipe sensor T2B) malfunction
E5
Over-voltage or under-voltage protection
E6
PFC module protection
E8
Outdoor fan speed malfunction
F1
No. A Indoor unit coil outlet temp. sensor malfunction
F2
No. B Indoor unit coil outlet temp. sensor malfunction
F3
No. C Indoor unit coil outlet temp. sensor malfunction
F4
No. D Indoor unit coil outlet temp. sensor malfunction
F5
No. E Indoor unit coil outlet temp. sensor malfunction
F6
No. F Indoor unit coil outlet temp. sensor malfunction
P0
High temperature protection: top of compressor
P1
High pressure protection
P2
Low pressure protection
P3
Current overload protection
P4
Temperature protection of compressor discharge
P5
Condenser high temperature protection
P6
Inverter module (IPM) malfunction
LP
Low ambient temperature protection
Table 15
For Indoor Error Codes, please refer to the indoor service manual.
Bosch Thermotechnology Corp. | 08.2020
Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Multi Zone Outdoor Units | 23
Indoor Display
F4
E1
——
F2/F1/F3/F6
P1
——
F5
——
——
——
——
——
——
P2
P6
P6
F0
——
——
P0
——