Bosch Climate 5000 Series Service Manual page 81

Ductless air conditioner / heat pump outdoor unit
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

Service Manual
4.
Disconnect the electronic expansion valve wire.
Figure 105
5.
Remove the electric heaters.
Figure 106
6.
Remove the grounding screws.
7.
Remove the wires (1,2,3 or L1,L2,S).Then remove the electronic control
box.
Figure 107
Bosch Thermotechnology Corp. | 04.2020
Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Outdoor Unit | 81
9.3.4 Removing the reversing valve
1.
First remove the panel plates and electrical parts.
2.
Recover refrigerant from the refrigerant circuit.
3.
Remove the screw of the coil (Fig.118, pos.1) and then remove the coil.
4.
Detach the welded parts (Fig.118, pos.2) of reversing valve and pipe.
Figure 108
Take care to protect internal components when removing copper piping.
5.
Then the reversing valve assembly can be removed.
1
2
Data subject to change

Hide quick links: