Error Codes - Bosch Climate 5000 SCI 18 CAS/ OU- OUE Owner's Manual

Cassette-type air conditioner
Table of Contents

Advertisement

5.3

Error Codes

• Inverter Split Type
Number
Cause
1
Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error
2
Indoor and outdoor unit communication malfunction
3
Indoor fan speed malfunction
4
Indoor room temperature sensor error
5
Evaporator coil temperature sensor error
6
Refrigerant leak detection system malfunction
7
Water level alarm malfunction
8
Dual indoor unit (twin model only) communication malfunction
9
Other twin model malfunction
10
Overload protection
11
Outdoor temperature sensor error
12
Outdoor condenser pipe sensor error
13
Discharge air temperature sensor error
14
Outdoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error
15
Outdoor fan speed (DC fan motor only) malfunction
16
Auto-lifting panel communication error
17
Auto-lifting panel malfunction
18
Auto-lifting panel is open
19
Inverter module IPM protection
20
High/low voltage protection
21
Compressor top overheating protection
22
Outdoor low-temperature protection
23
Compressor drive error
24
Mode conflict
25
Compressor low-pressure protection
26
Outdoor IGBT sensor error
Table 4.
Climate 5000 SCI – 6720887397 (2018/04)
Troubleshooting
Operation
Timer
Error
indicator
indicator
Code
flashes
1
Off
E0
2
Off
E 1
4
Off
E3
5
Off
E4
6
Off
E5
7
Off
EC
8
Off
EE
9
Off
E8
10
Off
E9
1
On
F0
2
On
F 1
3
On
F2
4
On
F3
5
On
F4
6
On
F5
8
On
F7
9
On
F8
10
On
F9
1
Flash
P0
2
Flash
P 1
3
Flash
P2
4
Flash
P3
5
Flash
P4
6
Flash
P5
7
Flash
P6
8
Flash
P7
9

Hide quick links: