Wiring Diagrams; Odu Pcb & Ipm - Bosch Climate 5000 Series Service Manual

Ductless air conditioner / heat pump outdoor unit
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

2 2 | Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Outdoor Unit

7 Wiring Diagrams

7.1 ODU PCB & IPM
7.1.1 PCB: Regular 115V Single Zone 12K
BMS500-AAS012-0CSXRB
Figure 12
Number
Name
1
Power Supply
2
S
3
HEAT1
4
4-WAY
5
AC-FAN
6
TP T4 T3
7
HEAT2
8
PMV
9
DC-FAN
10
FAN_IPM
11
TESTPORT
12
EE_PORT
13
MCUPORT
W
14
V
U
15
COMP_IPM
16
BR1
Table 16
Data subject to change
CN#
Description
CN3
Earth: connect to Ground
CN1
N_in: connect to N-line (100-130V AC input)
CN2
L_in: connect to L-line (100-130V AC input)
CN16
S: connect to indoor unit communication
CN17
connect to compressor heater, 100-130V AC when is ON
CN60
connect to 4 way valve, 100-130V AC when is ON.
CN25
connect to AC fan
CN21
connect to pipe temp. sensor T3, ambient temp. sensor T4, exhaust temp. sensor TP
CN15
connect to chassis heater, 100-130V AC when is ON
CN31
connect to Electric Expansion Valve
CN7
connect to DC fan
IPM 501
IPM for DC fan
CN6
used for testing
CN505
EEPROM programmer port
CN507
connect to PC communication
CN28
connect to compressor
CN29
0V AC (standby)
CN30
10-230V AC (running)
IPM 301
IPM for compressor
BR1
Bridge
Service Manual
04.2020 | Bosch Thermotechnology Corp.