Error Codes - Bosch Climate 5000 Series User Manual

Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

User Manual

5.2 Error Codes

CAUTION: SYSTEM FAILURE
 If below error codes appear, please turn off the system and
contact an Authorized Service Provider.
Number
Cause
1
Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error
2
Indoor and outdoor unit communication malfunction
3
Indoor fan speed malfunction
4
Indoor room temperature sensor error
5
Evaporator coil temperature sensor error
6
Refrigerant leak detection system malfunction
7
Water level alarm malfunction
8
Dual indoor unit (twin model only) communication malfunction
9
Other twin model malfunction
10
Overload protection
11
Outdoor temperature sensor error
12
Outdoor condenser pipe sensor error
13
Discharge air temperature sensor error
14
Outdoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error
15
Outdoor fan speed (DC fan motor only) malfunction
16
Inverter module IPM protection
17
High/Low voltage protection
18
Compressor top overheating protection
19
Outdoor low temperature protection
20
Compressor drive error
21
Mode confl ict
22
Compressor low-pressure protection
23
Outdoor IGBT sensor error
24
Indoor unit communication malfunction
Table 3
Bosch Thermotechnology Corp. | 06.2019
Bosch Climate 5000 Series Ducted Type (Medium & High Static) Air Conditioner / Heat Pump | 13
Operation indicator
Timer indicator
fl ashes
1
Off
2
Off
4
Off
5
Off
6
Off
7
Off
8
Off
9
Off
10
Off
1
On
2
On
3
On
4
On
5
On
6
On
1
Flash
2
Flash
3
Flash
4
Flash
5
Flash
6
Flash
7
Flash
8
Flash
11
On
Error Code
E0
E1
E3
E4
E5
EC
EE
E8
E9
F0
F1
F2
F3
F4
F5
P0
P1
P2
P3
P4
P5
P6
P7
FA
Data subject to change

Advertisement

Table of Contents
loading

Table of Contents