PCI-D96SU/D128SU Card
2.4 DIO Operating Voltage Jumper
Before installing the card into your computer, configure the DIO operating voltage according to your
requirements. Jumpers JP1 and JP2 are used to specify the DIO operating voltage levels. The
following illustrates the jumper positions used to select the digital signal voltage levels:
JP1
P1
P2
2-3
1-2
1-2
2-3
1-2
1-2
1-2
1-2
X
JP1
P1
P2 P3
1
1
2
2
3
3
P3
1-2
1-2
1-2
2-3
X
X
User Manual, Ver. 1.0, Apr. 2019, PMH-031-10 Page 9
JP2
1
1
2
2
3
3
JP2
2-3
2-3
2-3
2-3
1-2
Voltage
+1.5 V
+1.8 V
+2.5 V
+3.3 V
+5.0 V (Default)