Mute Switching; Output Level Control; Scene Recall - Yamaha WK83840 Owner's Manual

Yamaha digital mixing engine owner's manual
Table of Contents

Advertisement

Mute Switching

Turns the DME64N/24N output mute function ON or
OFF.
1.
Press the [MUTE] key.
The Mute Parameter Edit display will appear.
2.
Select Mute ON or OFF.
The mute function is turned on or off as described in
"ON/OFF Parameters" on page 38.
NOT E
To access this function from the ICP1 control panel, hold the
[F6] key for longer than 2 seconds.
NOT E
All outputs in the device group, including the [PHONES] jack,
are muted.

Output Level Control

Adjust the output level of the DME64N/24N.
NOT E
Output level settings apply individually to each DME64N/24N
unit. There is no overall device group setting.
This function cannot be accessed from the ICP1 control panel.
1.
Press the [LEVEL] key.
The "Output Level" Parameter Edit display will appear.
2.
Adjust the numeric output level parameter as
required.
The Output Level parameter is adjusted as described in
"Numeric Parameters" on page 36. The graphic fader
provides a visual indication of the current output level
setting.

Scene Recall

This procedure recalls a new scene (refer to page 10).
N OTE
The same procedure is used for scene recall from an ICP1 control panel.
1.
Press the [SCENE] key.
The Scene Recall display will appear.
2.
Select a new scene.
Scenes are selected as described in the "List Parameters"
section on page 38.
3.
Press the [ENTER] key.
A confirmation window will appear.
4.
Press the [ENTER] key again.
The new scene will be selected.
Don't turn the power off during a scene recall
operation. Doing so can cause corruption of the
CAUTION
current scene data.
DME64N/DME24N Owner's Manual
Parameter Edit Displays
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dme64nDme24n

Table of Contents