Page 1
Réf. 3195 - 4.33/d - 12.99 VARMECA - 10 Variable speed motor or geared motor installation and maintenance...
Page 2
Variable speed motor or geared motor NOTE LEROY-SOMER reserves the right to modify the characteristics of its products at any time in order to incorporate the latest technological developments. The information contained in this document may therefore be changed without notice.
Page 3
LEROY-SOMER INSTALLATION AND MAINTENANCE Réf. 3195 - 4.33/d - 12.99 VARMECA - 10 Variable speed motor or geared motor SAFETY AND OPERATING INSTRUCTIONS FOR ELECTRICAL ACTUATORS (In accordance with the low voltage directive 73/23/EEC modified by 93/68/EEC) 4 - Installation •...
The motor allows all kinds of mounting arrangements (foot or flange) and can be combined with standard gearboxes from the LEROY-SOMER range. In the standard version, the integrated speed controller does not require any connection other than the power supply.
Page 6
LEROY-SOMER INSTALLATION AND MAINTENANCE Réf. 3195 - 4.33/d - 12.99 VARMECA - 10 Variable speed motor or geared motor GENERAL INFORMATION 1.3.2 - Specifications and functions SPECIFICATIONS VARMECA - 10 Overload 150 % of In for 40s, 10 times per hour...
LEROY-SOMER INSTALLATION AND MAINTENANCE Réf. 3195 - 4.33/d - 12.99 VARMECA - 10 Variable speed motor or geared motor GENERAL INFORMATION Specifications and functions (continued) PROTECTIONS VARMECA - 10 Power • Undervoltage • Overvoltage • Overloads : - overheating, speed controller and motor - protection against locked rotor •...
LEROY-SOMER INSTALLATION AND MAINTENANCE Réf. 3195 - 4.33/d - 12.99 VARMECA - 10 Variable speed motor or geared motor INSTALLATION 2 - INSTALLATION 2) Remove the control button and cable gland support fastening screws (TORX 10 + slot type screws).
LEROY-SOMER INSTALLATION AND MAINTENANCE Réf. 3195 - 4.33/d - 12.99 VARMECA - 10 Variable speed motor or geared motor CONNECTIONS 3 - CONNECTIONS • With CVI - VMA option Fault relay terminal block • The voltages on the power terminal blocks and the cables connected to them may cause fatal electric shocks.
LEROY-SOMER INSTALLATION AND MAINTENANCE Réf. 3195 - 4.33/d - 12.99 VARMECA - 10 Variable speed motor or geared motor CONNECTIONS 3.2.4 - Control terminal block 3.2.5 - Fault relay terminal block This is located on the side printed circuit and used for remote Ref.
• Locked motor rotor • Check that the deceleration ramp is long enough (5s) for • Faulty insulation of a applications with high inertia. winding • If the fault remains, consult LEROY-SOMER • Overheating I • Internal fault Flashing red • Undervoltage •...
LEROY-SOMER INSTALLATION AND MAINTENANCE Réf. 3195 - 4.33/d - 12.99 VARMECA - 10 Variable speed motor or geared motor MAINTENANCE 6 - MAINTENANCE 6.2 - Measurements 6.2.1 - General • All work relating to installation, commissioning and maintenance must be carried out by The input voltages can be measured using ordinary experienced and qualified personnel.
LEROY-SOMER INSTALLATION AND MAINTENANCE Réf. 3195 - 4.33/d - 12.99 VARMECA - 10 Variable speed motor or geared motor MAINTENANCE 6.3 - Spare parts Description Part code Ref. Control button + indicator lamp kit (BD or BG) AEM905KB001 Kit without control button (SD or SG)
LEROY-SOMER INSTALLATION AND MAINTENANCE Réf. 3195 - 4.33/d - 12.99 VARMECA - 10 Variable speed motor or geared motor OPERATING EXTENSIONS 7 - OPERATING EXTENSIONS 7.1 - Option without control button (SD or SG) The speed control button is no longer located on the VARMECA - 10 (the indicator lamp remains) but near the operator.
LEROY-SOMER INSTALLATION AND MAINTENANCE Réf. 3195 - 4.33/d - 12.99 VARMECA - 10 Variable speed motor or geared motor OPERATING EXTENSIONS 7.5 - Integrated speed adjustment 7.6 - Electromechanical brake option option (CVI-VMA) The motor must be fitted with an FCR brake adapted for the VARMECA - 10.
Need help?
Do you have a question about the VARMECA-10 and is the answer not in the manual?
Questions and answers