9 "SINAMICS V90 PN" Demo Case
9.3 Operating the application example
5. Apply the values in the drive
6. Permanently save the values in the drive (copy RAM to ROM)
7. Upload the values from the drive into the TIA Portal project.
9.3
Operating the application example
The operation of the example application corresponds to the approach introduced
in chapter 8.5.
9.3.1
Differences of the simulation example application
The following differences of the example application of the "SINAMICS V90 PN"
demo case exist:
A new product is detected via the measuring input signal that is triggered via
the pushbutton function of the toggle switch S15 (press gear lever to the right).
This is why the "New product" button on the user interface is without function.
The S15 (1) toggle switch is directly connected to channel 2 of the TM Timer
DIDQ technology module of the demo case.
The cam switch signal for controlling the value for applying the material is
output via the LED H15 (2) of the demo case.
Figure 9-3 Operator panel of the "SINAMICS V90 PN" demo case
9.3.2
Functional differences
A measuring pulse (rising edge) is triggered via the S15 toggle switch on the TM
Timer DIDQ technology module. This measurement is now tangibly performed on
the demo case via the "MC_MeasuringInput" instruction. The currently detected
TOs of S7-1500(T)
Entry ID: 109743134,
V1.0,
05/2017
1
2
58