9 "SINAMICS V90 PN" Demo Case
9.1 Overview of the demo case
Figure 9-2 Wiring of the "SINAMICS V90 PN" demo case
PG
X150P1
9.1.4
Functions
The following functions can be used via the operating elements of the demo case
in interaction with the user program:
Digital inputs via switch (S1...S15)
Digital outputs via LED (H1...H15)
Analog inputs 0...10V (left and right)
Emergency stop directly wired to the drives and switched time-delayed via a
settable delay element (0s...2s)
Measuring input of the TM Timer DIDQ technology module via light barrier
(axes) and toggle switch (S16)
Cam output of the TM Timer DIDQ technology module via LED (H16) and LED
between the axes
TOs of S7-1500(T)
Entry ID: 109743134,
V1.0,
CPU1515T
(192.168.0.1)
X1P1
X1P1
X1P2
X150P2
X150P1
V90Left
(192.168.0.3)
Name: Drive_1
05/2017
ET200SP
(192.168.0.2)
X1P2
V90Right
(192.168.0.4)
Name: Drive_2
AI 2xU
00: P1
01: P2
TM Timer DI
00: Sensor 0° V90Left
01: Sensor 0° V90Right
02: S15
TM Timer DQ
02: H15
04: LED between Drives
(using Switch „Sync")
DQ16x24VDC
00: H0
...
14: H14
DI16x24VDC
00: S0
...
14: S14
15: E-Stop
Switch „Sync"
DQ4: LED connected to
DQ4 of TM Timer
P24: LED always ON
(using +24V)
56