Pitco MGII Technical Service And Exploded Parts page 7

Hide thumbs Also See for MGII:
Table of Contents

Advertisement

CONVERSION INSTRUCTIONS FOR SG
MODEL FRYERS
1) Following the Fryer Start-up and Shut Down
instructions following in this manual, shut the appliance
off and allow the appliance to cool to room temperature.
Insure that gas supply shut-off valve (located on the gas
supply pipe before the fryer operating gas valve) is in the
"OFF" position. Remove main burners.
2) Remove all burner orifices and replace them with the
appropriate orifices for the new gas type (refer to Table
1 for proper orifice size, that will match gas type conver-
sion). Make sure that an approved gas sealant is
applied to the orifice threads before installing the orifices
to the main burner manifold (remove burners if neces-
sary to replace orifices).
3). Burners must also be replaced if changing from LP
to NAT or NAT to LP according to the chart below.
Any gas type marked as NAT uses burner part
#B8037303 vertical slotted face burner, any gas type
marked as LP uses part #B80320001 screen mesh face
burner.
Applicable
Country(s)
GB, IE
GB-GreatBritan,IE-Ireland
Appliance
Model
Number
Nat
MGII
LP
Nat
MGIIT
LP
Table 1 Orifice Tips
NON-CE COUNTRIES
Model
MG2
MG2S
CE COUNTRIES
Model
MG2
MG2S
G20
I
2H
23.4
G31
I
3P
G20
I
2H
23.4
G31
I
3P
Gas Type
NAT
LP
#46
#55
#46
#55
Gas Type
G20
G31
#46
#55
#46
#55
NOTE: If unit is being converted from LP to
Natural gas or Natural to LP gas, the pilot orifice
and regulator (on gas valve) must also be re-
placed with appropriate orifice and gas type regula-
tor.
4) If burners were removed, reinstall them and turn gas
supply shut-off valve to the "ON" position. Refer to
lighting instructions and relight the appliance. With
burners on, check for any gas leakage around the
orifices.
5) With main burners operating, check burner manifold
pressure and insure that proper gas pressure is supplied
to the burner system (refer to Table 2 for pressure
settings). Adjust if necessary.
6) Finally, apply the gas type conversion label, pro-
vided with the conversion kit, just below the fryer data
plate on the fryer door inside panel.
21.1
20
10
21.5
50/37
25.4
21.1
20
10
21.5
50/37
25.4
Table 2 Burner Pressure
NON-CE COUNTRIES
Model
MG2
MG2S
CE COUNTRIES
Model
MG2
MG2S
7
#46
N22
YES
#55
LP16
YES
#46
N22
YES
#55
LP16
YES
Gas Pressure
(in W.C.)
NAT
LP
4.0
10.0
4.0
10.0
Gas Pressure
(mbar)
G20
G31
10
25.4
10
25.4
L22-236 Rev 0 (04/03)
2.2
0.9
2.2
0.9