Download Print this page

Felton CARE FCSMCA Installation Manual

Sink mixer

Advertisement

Quick Links

INSTALLATION GUIDE - AUSTRALIA
FELTON CARE SINK MIXER FCSMCA
SYSTEM REQUIREMENTS
To ensure the optimum performance and customer satisfaction please adhere to the following:
• Flush out all pipe work prior to installation.
• Maximum hot water temperature is 60˚C. If the water temperature exceeds 60˚C an approved tempering valve must
be fitted.
• Installation should comply with relevant local authority requirements.
• In accordance with good plumbing practice, filters should be fitted to supply lines to eliminate damage to the
ceramic cartridge from suspended solids.
• AS/NZS 3500.1 states that pressures above 500kPa can cause damage from water hammer, reduce the life of
appliances, taps & fittings, cause excessive noise in the system and recommend that a pressure limiting valve (PLV)
be fitted.
MAXIMUM STATIC PRESSURE
Maximum static pressure 1500kPa. If water
pressure exceeds or is likely to exceed
1500kPa, an approved pressure limiting
valve must be fitted.
Failure to comply with the above will void warranties
WHAT IS IN THE PACK
1 x sink mixer
2 x supply hoses
HOW TO INSTALL
1.
Cut a mounting hole 35mm in diameter. There must be a minimum 20mm width of flat around the hole.
2.
Fit flange o-ring seal to flange and then fit the flange onto the mixer.
3.
Screw the two stud fixing into mixer base.
4.
Screw the "HOT" supply hose (with RED marking) into 'H' hole of mixer base (with RED marking).
5.
Screw the "COLD" supply hose into the remaining 'C' hole of mixer base.
6.
Lower the fitted supply hoses, one hose at a time, into mounting hole.
7.
From UNDERNEATH the bench, fit rubber horseshoe washer (if supplied) and metal horseshoe washer
around both hoses and over the threaded studs.
8.
Screw on the M6 nut and tighten with your fingers.
9.
Check that the mixer and bench top seal are correctly aligned on the bench. Secure with a spanner.
10.
Flush the supply pipes to remove debris.
11.
Turn on water supply and check for leaks.
Maximum bend for flexible hose is 35mm radius. The nipples on the hoses must be connected to fittings which have
machined end faces, not "sawn o " threaded tube.
MINIMUM STATIC PRESSURE
Mains Pressure
1 x benchtop o-ring
1 x sink fixing kit
HOT
COLD
150kPa
150kPa

Advertisement

loading

Summary of Contents for Felton CARE FCSMCA

  • Page 1 INSTALLATION GUIDE - AUSTRALIA FELTON CARE SINK MIXER FCSMCA SYSTEM REQUIREMENTS To ensure the optimum performance and customer satisfaction please adhere to the following: • Flush out all pipe work prior to installation. • Maximum hot water temperature is 60˚C. If the water temperature exceeds 60˚C an approved tempering valve must be fitted.
  • Page 2 Warranty, Maintenance and Care YOUR COPY TO KEEP Felton Australia Pty Limited guarantees these mixers to be free from defects in materials and workmanship for a period of fifteen (15) years from the date of purchase. Fair wear and tear is expressly excluded. This warranty is e ective for fifteen (15) years from the date of purchase and covers the supply of replacement parts only and 2 years of plumber’s labour from the date of purchase relating solely to repairing or replacing the mixer, provided the product is installed by a...