SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock,
or other conditions which may cause death, personal injury or
property damage.
Consult a qualified installer, service agency, or your distributor
or branch for information or assistance. The qualified installer
or agency must use factory-authorized kits or accessories when
modifying this product. Refer to the individual instructions
packaged with kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective
clothing and work gloves. Have a fire extinguisher available.
Read these instructions thoroughly and follow all warnings or
cautions included in the literature and attached to the unit.
Consult local building codes and the current editions of the
National Electrical Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian
Electrical Code CSA C22.1. Recognize safety information.
This is the safety-alert symbol
on the unit and in instruction manuals, be alert to the potential
for personal injury.
WARNING
The 9K and 12K units are for single room applications only.
WARNING
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury or
death.
Before installing or servicing unit, always turn off all power to the
unit. There may be more than one disconnect switch. Turn off the
accessory heater power if applicable. Lock out and tag switch
with a suitable warning label.
2
. When you see this symbol
Specifications subject to change without notice.
WARNING
EXPLOSION HAZARD
Failure to follow this warning could
result in death, serious personal injury,
and/or property damage.
Never use air or gases containing oxygen
for leak testing or operating refrigerant
compressors. Pressurized mixtures of air
or gases containing oxygen can lead to
an explosion.
CAUTION
EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage or
improper operation.
Do not bury more than 36 in. (914 mm) of refrigerant pipe in the
ground. If any section of pipe is buried, there must be a 6 in. (152
mm) vertical rise to the valve connections on the outdoor units. If
more than the recommended length is buried, refrigerant may
migrate to the cooler buried section during extended periods of a
system shutdown. This causes refrigerant slugging and could
possibly damage the compressor during the start-up process.
CAUTION
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use caution and
wear appropriate protective clothing and gloves when handling
parts.
IM-40MBDQ-05