INTRODUCTION

The Ducted Slim models are R-410A fan coils designed with
application flexibility in mind. The 9K-48K sizes can be
mounted horizontally or vertically (upflow) while the 58K size
can be mounted only horizontally.
A rear and bottom return is available for field modification on
the 9K-48K sizes to match the different applications.
All these fan coils have a DC fan motor with variable speeds
for efficiency and comfort. The static pressure can be manually
set up or use the constant air volume control.
The ducted fan coil unit is shipped with a condensate lift pump
providing a maximum lift of 29.5in (750mm).
ACCESSORIES
The system is shipped with the following accessories. Use all
of the installation parts and accessories to install the system.
Improper installation may result in water leakage, electrical
shock and fire, or cause the equipment to fail. Keep the
installation manual in a safe place and do not discard any other
accessories until the installation work has been completed.
Table 1 — Accessories
ACCESSORY
Literature package including
owner's manuals, installation
instructions and warranty card
Soundproof/insulation sheath
Brass flare nut
Drain adapter
Air filter
Wired controller
Wireless remote controller
Infrared Display Panel and
extension wire
Condensate Lift Pump (external
sizes 09K-18K, internal sizes
24K-58K)
EMC Ferrite core (magnetic ring)
Optional Return Temperature
Sensor p/n 40VM900009 - sold
separately
IM-40MBDQ-05
QUANTITY
SHAPE
3
2
2
1
1
1
1
1
1
1
1
Specifications subject to change without notice.
Air inlet
Air outlet
screw
Fig. 3 — Indoor Unit Representation
NOTES:
- If the outdoor unit is higher than the indoor unit, prevent rain
from flowing into the indoor unit along the connection pipe by
creating a downward arc in the connection pipe before it
enters the wall and enters the indoor unit. Doing so helps
ensure rain drips from the connection pipe before it enters the
wall.
- Piping and the interconnecting wiring are field supplied.
- Fig. 3 is a sketch. Different models may differ slightly.
Table 2 — Indoor Unit Model Numbers
KBTUH
V-PH-HZ
9
12
18
24
208/230-1-60
36
48
58
Air filter
(on some models)
Drain hose
Refrigerant connecting pipe
Air filter
ID MODEL NO.
40MBDQ09---3
40MBDQ12---3
40MBDQ18---3
40MBDQ24---3
40MBDQ36---3
40MBDQ48---3
40MBDQ58---3
3