Full Internal Cleaning (Soak Wash) - Hardi NK SB Series Instruction Book

Table of Contents

Advertisement

Rinsing when main tank is not empty
Rinsing the pump, operating units, spray lines, etc. in case of stop in spraying (e.g. because of rain), before main tank is empty.
Cleaning of the liquid system:
1. Turn suction valve towards
2. Close AgitationValve (no agitation).
3. Engage the pump. Set the pump speed to approximately 300 rpm and increase the spraying pressure to 6 bar. Spray
the water from the rinsing tank into the field, until all nozzle tubes and nozzles have been flushed with clean water.
4. Disengage the pump.
μ
ATTENTION! It is advisable to increase the forward speed (double, if possible), when spraying diluted remaining liquid
in the field just sprayed.
Cleaning the sprayer on the outside
±
WARNING! External cleaning with a spray gun is only possible with emptied and cleaned main tank. Do a complete
main tank cleaning, before attempting to use the spray gun!
1. Turn suction valve towards
2. When another 1/3 of the contents in the rinsing tank is transferred to the main tank, turn the suction valve towards
. Adjust the spraying pressure to 8 - 10 bar.
3. Open the (manual) External Cleaning Device valve at the operating unit and wash the sprayer with the cleaning device
located on sprayer's rear side. If necessary, the pressure can be adjusted on the pressure regulation valve.
4. Disengage pump again.
μ
ATTENTION! If the sprayer is cleaned with a high pressure washer, lubrication of the entire machine is recommended.

Full Internal Cleaning (Soak Wash)

μ
ATTENTION! This cleaning procedure is always used, if one or more of these situations occur:
A. The next crop to be sprayed is at risk of being damaged by the chemical just used.
B. The sprayer is not going to be used right away for the same chemical or crop.
C. Before any repair or maintenance job is going to be carried out on the sprayer.
μ
ATTENTION! Washing the sprayer between jobs with incompatible crops must be done according to prescriptions
from the chemical manufacturer. Use e.g. AllClearExtra, as this is a commonly used cleaning agent. If your chemical
prescribes another cleaning agent and/or another cleaning procedure, you must follow that.
Procedure for washing with a cleaning agent, such as AllClearExtra:
1. Rinse the sprayer in the field (See the section "Use of Rinsing Tank and Rinsing Nozzles").
2. Drive to the filling location.
3. Prepare sprayer for cleaning with cleaning agent. Fill water in the main tank to 10% of its capacity. Fill the rinsing tank
completely. This water is later used for rinsing.
4. Turn suction valve towards "Main tank" and pressure valve towards "Tank cleaning nozzle". Set agitation valve to
"Agitation".
5. Engage and set the pump speed at approximately 300 rpm.
6. Allow the liquid to circulate the system for 3 minutes.
7. Close all valves for minimum 10 seconds in order to burst and flush the safety valve.
8. Open the ChemFiller enable valve, the ChemFiller transfer valve and the flush valve. Allow the liquid to circulate for 3
minutes.
. (Keep pressure valve in
and close the other valves.
-position).
5 - Operation
81

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nk mb series

Table of Contents