Indicator Light Flashing Sequences - Xantrex XC1524 Owner's Manual

12v / 30a / 50a and 24v / 15a / 25a battery charger
Hide thumbs Also See for XC1524:
Table of Contents

Advertisement

Indicator Light Flashing Sequences

Table 4-1 Indicator Light Sequences on the XC Series
Activity
Charging indicator light illuminates
Charging indicator light flashes
Ready indicator light illuminates
Fault indicator light illuminates
Fault indicator light flashes
Charging current indicator lights
illuminate
Charging current indicator lights
flash
Charging current indicator lights
flash,
Fault indicator light illuminated
975-0187-01-01
Indicator Light Flashing Sequences
Charger status
The unit is charging in bulk or absorption mode
The unit is performing the equalization charge.
(Charging indicator light flashes once every four
seconds if bank 1 is being equalized, twice every
four seconds if bank 2 is being equalized, and
three times every four seconds if bank 3 is being
equalized)
The unit is either in float mode of three stage
charging or rest mode of two stage charging. All
batteries have been fully charged.
Any fault condition that prevents the charger from
charging one or more banks, but is not a charger
fault condition - remote display shows details of
fault. Example:
E r r B A T P o L
polarity detected)
Charger fault condition - remote display shows
followed by
. The charger is damaged,
e r r
C H f
contact service.
These lights indicate the charging current. At
transition points when the current is changing, two
indicator lights may flash alternately, then settle
into the new charging current reading.
100% indicator light flashes to indicate battery
temperature too high warning (> 50 °C, 122 °F)
10% indicator light flashes to indicate battery
temperature too low warning (< 0 °C, 32 °F)
25% indicator light flashes to indicate that a
battery has been disqualified (see page 3–4)
100% indicator light flashes to indicate battery
temperature too high fault (> 55 °C, 131 °F)
10% indicator light flashes to indicate battery
temperature too low fault (< -20 °C, -4 °F)
(battery reverse
4–3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xc3012Xc2524Xc5012

Table of Contents