Download Print this page

OKIDATA B6300 Remanufacturing Instructions page 4

Uninet imaging

Advertisement

UNINET IMAGING INC. • OKIDATA® B6300 REMANUFACTURING INSTRUCTIONS
22. Carefully remove the drum.
25. Remove the wiper blade by unscrewing the two gold-colored screws at each end that
hold it in place as shown.
27. You are now ready to clean the wiper
blade and waste hopper.
www.
uninet
imaging.com
11124 Washington Blvd., Culver City, California U.S.A. 90232 Ph: 310 280-9620 • Fx: 310 838-7294 • techsupport@uninetimaging.com
© 2005 Uninet Imaging Inc. All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
23. You are now ready to remove the PCR.
28. Use air pressure to blow out any
remaining toner.
USA
EUROPE
Ph:
+310-280-9620
+34-93-757-1335
Fx:
+310-838-7294
+34-93-741-4166
24. Remove the PCR by un-clipping it from
the white and black holders.
26. Lift the wiper blade evenly from the
waste hopper.
29. Once clean, you are now ready to
reassemble t he wiper blade.
JAPAN
BRAZIL
+81-3-44-55-2789
+55-11-4822-3033
+310-838-7294
+55-11-4822-3353
ARGENTINA
+54-11-4574-3706
+54-11-4574-3706

Advertisement

loading