Grounding - Graco A Series Instructions-Parts List Manual

Air-driven agitators
Hide thumbs Also See for A Series:
Table of Contents

Advertisement

Installation

Grounding

For a ground wire and clamp, order Part No. 237569.
Proper grounding is an essential part of maintaining a
safe system.
To reduce the risk of static sparking, the mounting cov-
er and all electrically conductive objects or devices in
the spray area must be properly grounded. Check
B
your local electrical code for detailed grounding
A
instructions for your area and type of equipment.
Fig. 2
To ground the agitator, connect one end of the
ground wire (A) to the ground connector (B) on the rim
of the drum cover. See Fig. 2. Connect the other end
of the ground wire to a true earth ground.