Applications; Pumped Liquids; Sound Pressure Level; Drinking Water - Grundfos SP Series Installation And Operating Instructions Manual

Table of Contents

Advertisement

4. Applications

Grundfos SP submersible pumps are designed for a wide range
of water supply and liquid transfer applications, such as the
supply of fresh water to private homes or waterworks, water
supply in horticulture and agriculture, drawdown of groundwater
and pressure boosting, and various industrial jobs.
The pump must be installed so that the suction interconnector is
completely submerged in the liquid. The pump can be installed
horizontally or vertically. See section

4.1 Pumped liquids

Clean, thin, non-explosive liquids without solid particles or fibres.
The maximum sand content of the water must not exceed
50/100/150 ppm. A larger sand content will reduce the life of the
pump and increase the risk of blockage.
Pump type
SP 1A - SP 5A
SP 7 - SP 14
SP 17 - SP 60
SP 77 - SP 215
When pumping liquids with a density higher than
water (998-1000 kg/m
higher outputs must be used.
If liquids with a viscosity higher than that of water are to be
pumped, contact Grundfos.
N EN 1.4401 and R EN 1.4539 grade stainless steel pump sets
are designed for liquids more aggressive than drinking water.
The maximum liquid temperature appears from section
temperatures and motor
cooling.
4
5.2 Positional
requirements.
Maximum content of sand
[ppm]
50
150
100
50
3
), motors with correspondingly
5.4 Liquid

4.2 Sound pressure level

The sound pressure level has been measured in accordance with
the rules laid down in the EC machinery directive 2006/42/EC.
Sound pressure level of pumps
The values apply to pumps submerged in water.
Pump type
SP 1A
SP 2A
SP 3A
SP 5A
SP 7
SP 9
SP 11
SP 14
SP 17
SP 30
SP 46
SP 60
SP 77
SP 95
SP 125
SP 160
SP 215
Sound pressure level of motors
The sound pressure level of Grundfos MS and MMS motors is
lower than 70 dB(A).
Other motor brands: See installation and operating instructions
for these motors.

4.3 Drinking water

If the product is used for drinking water, the following precautions
must be taken to avoid contamination:
Before use, make sure that the product does not come into
contact with dust or with chemicals not suitable for contact
with drinking water, for example lubricants, greases or oils.
If the pump is used with potentially toxic liquids, it can no
longer be used for drinking water.
In case of maintenance, be sure to always use original parts to
maintain the initial hygienic characteristics of the product.
L
[dB(A)]
pA
less than 70
79
79
82

Hide quick links:

Advertisement

Table of Contents
loading