CHAPTER 3: INSTALLING ASHBY LOUDSPEAKERS
The pendant includes a top cover to hide the back of the
loudspeaker and wiring connectors making them perfect for
installations where they may be viewed from above. The top
cover includes:
Holes with protection grommets for cables;
A center hole for a threaded rod;
Three tabs for steel wires (not included) for a single hang
point. The tabs must be bent up before use.
The Ashby-5C and Ashby-8C have separate pendant models.
See "Ashby Pendant Dimensions" on page 31.
You can order Ashby pendants using the following part
numbers:
Ashby-8C Pendant: PN 40.260.030.01
Ashby-5C Pendant: PN 40.261.030.01

WIRING THE LOUDSPEAKER

1. Prepare the wires.
The loudspeaker provides a strain relief fitting for bare
wires, 1/2-in flexible metal conduit, or 1/2-in 14 NPSM
threaded conduit adapters.
2. For bare wires or conduit without a threaded conduit
adapter, open the wiring cover, loosen the L-bracket
screws, and remove the clamping screws.
To finish wiring a conduit with a threaded conduit
adapter, see the next procedure.
Figure 11: Removing clamping screws
3. Insert the cable or 1/2-in flexible metal conduit into the
input or looping connector and feed the wires through the
L-bracket opening.
4. Close and latch the wiring cover, and clamp the wire or
conduit with the L-brackets.
18
Figure 12: Clamping the wire
For installations using a threaded conduit adapter:
1. Open the wiring cover and completely remove the L-
brackets.
2. Install the threaded adapter, insert the conduit, and con-
nect the wires.
3. Close and latch the wiring cover.
Figure 13: Clamping a conduit