TTS
4.2.4 Three-piece lever (nominal (rated) torque 3 kN@m)
• First attach the connection bolt of the lever with two of the supplied hexa-
gon-socket screws (a./f. 5) in the measuring head. Make sure you get the
right end, as shown in Fig. 4.14.
• Push the center piece over the connection bolt and tighten the fastening
screws.
• Now push the end piece into the center piece and turn the fastening screws
tight.
Connection
bolt
Fig. 4.13: Three-piece lever (3 kN@m)
20 mm
Measuring head
end
Fig. 4.14: Detailed view of end orientation on the connection bolt
A1571-1.2 de/en
Center piece
Lever end
70 mm
31
End piece
HBM