Summary of Contents for Rossmax AC1000f

  • Page 1 AC1000f Model: Blood Pressure Monitor www.rossmax.com...
  • Page 2: Table Of Contents

    PARR (Pulse Arrhythmia) Technology ..................9 cilities. The patient is an intended operator. Do not use this device on infants or neonates. AC1000f is protected against manufacturing defects by an estab- Atrial Fibrillation Detection (AF, AFib) ................9-10 lished International Warranty Program. For warranty information, you can con- Premature Contraction Detection (PC) ..............10-11...
  • Page 3: Notes On Safety

    blood, kidney problems, or for users suffered from stroke, or for unconscious 19. Avoid any mechanical restriction, compression or bending of the cuff line. users. 20. Do not allow sustained pressure in the cuff or frequent measurements. The 8. This unit is able to detect common arrhythmia (atrial or ventricular premature resulting restriction of the blood flow may cause injury.
  • Page 4: Name/Function Of Each Part

    • Do not use any cuff other than the models exclusive for this unit. Name/Function of Each Part • Do not use this unit on infants. • Do not use this unit on patients using a pump oxygenator. • Do not use an AC adaptor or battery pack no specified for this unit. Charging •...
  • Page 5: Parr (Pulse Arrhythmia) Technology

    Monitor Installation - Trolley (Optional) PARR (Pulse Arrhythmia) Technology Pulse Arrhythmia (PARR) technology specifically detects the existence of Placing Protection Jelly pulse arrhythmia, including atrial fibrillation (AF, AFib), Atrial and / or Ventricu- onto the Monitor lar Premature Contractions (PC), Tachycardia (TACH), and Bradycardia (BRAD). Pulse Arrhythmia may be related to cardiac disorders, needs medical atten- tion and thus early diagnosis is of paramount importance.
  • Page 6: Premature Contraction Detection (Pc)

    Atrial fibrillation most often initially occurs with temporary periods of arrhyth- Note: It is strongly recommended, that you consult your physician, if either mia and may progress to a permanent state of this disorder in the course of the PC icon occurs newly for several times, or, if your PC is known to time.
  • Page 7: Pulse Arrhythmia Detection (Arr)

    Pulse Arrhythmia Detection (ARR) Real Fuzzy Measuring Technology Once the occurrence of pulse arrhythmia has been detected in the course of This unit uses the oscillometric method to detect your blood pressure. Be- your blood pressure measurement, the icon ARR is displayed. In the case, that fore the cuff starts inflating, the device will establish a baseline cuff pressure the found pulse arrhythmia can be specified by the PARR technology, the equivalent to the air pressure.
  • Page 8: Display Explanations

    Display Explanations Loose Cuff Detection If the cuff was applied too loosely, it may cause unreliable measurement re- sults or measurements can fail to start. The “Cuff Wrap Detection” can help to 1. Arrhythmia Detection determine if the cuff is wrapped snugly enough. The specified icon appears (ARR) once a “loosen cuff”...
  • Page 9: How To Use The Power Source

    Caution: Output: 7.5V 1.5A (Ø3.8 / Ø1.35) Brand: ROSSMAX • Do not short-circuit the polarities of the optional battery pack with a Manufacurer: HON-KWANG metal object such as wire. • If the fluid in the battery is stained on your skin or clothes, immediately •...
  • Page 10 How to Use the POWER Source How to Use the POWER Source Battery life: • You can use the unit for approximately six hundred measurements with one charge. • Approximate life of battery pack is two years. However the battery pack life from each charging may be shortened depending on the state of using.
  • Page 11: Applying The Cuff

    Applying the Cuff 1. Select cuff according to arm size: 3. Place the cuff over the bare upper arm, wrap it with the tube point- Rossmax Cuff size circumference ing your palm, and the artery mark over your main artery.
  • Page 12: Measurement Procedures

    Applying the Cuff Measurement Procedures Here are a few helpful tips to help you obtain more accurate readings: AUTO Mode: MANUAL • Blood pressure changes with every heartbeat and is in constant fluctuation without Mode: Stethoscope throughout the day. with Stethoscope •...
  • Page 13 Measurement Procedures Measurement Procedures Korotkoff sound of Systolic pressure 3. Auto Mode • In Auto mode, mark appears on the display. • Press the START key, the monitor will automatically inflate the cuff slowly to start measurement. Korotkoff sound of •...
  • Page 14: Setting Deflation Rate

    Setting Deflation Rate Clearing Values from Memory In the Manual mode, select the deflation rate of 2.5 mmHg/sec, 4.5 Under Auto mode, press and hold the Memory key for approximately 5 sec- mmHg/sec, 6.5 mmHg/sec by pressing the key on the back of the onds, then the data can be erased automatically.
  • Page 15: Specifications

    Deflation : Automatic Pressure Release Valve The AC1000f is intended for use in the electromagnetic environment specified below. The cus- tomer or the user of the AC1000f should assure that is used in such and environment. Memory capacity : 7 memories...
  • Page 16: Blood Pressure Log

    Blood Pressure Log Blood Pressure Log...
  • Page 17 WARNING: The symbol on this product means that it's an electronic product and following the European directive 2012/19/EU the electronic products have to be disposed on your local recycling centre for safe treatment. Rossmax Swiss GmbH, Widnauerstrasse 1, CH-9435 Heerbrugg, Switzerland...