15.0 LED codes

Beep
1/sec
1/min
1/min

16.0 Troubleshooting

The unit does not turn on.
The LEDs flash in the following order, red, blue,
green.
The red LED is flashing and the blue LED is solid.
The alarm does not activate when the float switch
is lifted.
The alarm does not activate when pressing the
'TEST' button
Alarm continuously active.
14
Red LED
Blue LED
3/sec
1/5sec
Any
Solid
Any
1/sec
All flash in sequence
Various
Solid
3/sec
Solid
Fault
Green LED
High water alarm
1/sec
Mains failure
Any
Error - Call support
Any
Service required
2/sec
High water has occurred
1/sec
All OK
Battery too low to start up
Serious internal error
Float cable issues
Battery is flat - charge the battery by connecting
mains supply to alarm unit.
Still doesn't turn on after 3 mins - alarm unit is
faulty.
Low battery - charge the battery by connecting
mains supply to alarm unit.
Float switch cable is faulty - check float switch
connections and cable for damage.
Float switch is broken - replace float switch.
Float cable is broken - replace float switch.
Faulty unit.
Float has been incorrectly wired - check the cables
are connected correctly.
Finger float has been installed upside down.