English
Thank you for placing your trust in our company by purcha-
sing the Weller WHA 300 Hot Air Station. Production was
based on stringent quality requirements which guarantee the
perfect operation of the device.

1. Caution!

Please read these Operating Instructions and the attached
safety information carefully prior to initial operation. Failure
to observe the safety regulations results in a risk to life and
limb.
The manufacturer shall not be liable for damage resulting
from misuse of the machine or unauthorised alterations.
The Weller WHA 300 Hot Air Station corresponds to the EC
Declaration of Conformity in accordance with the basic safe-
ty requirements of Directives 89/336/EEC and 73/23EEC.

2. Description

The WHA 300 hot air station was developed for gentle solde-
ring tasks on large-surface SM components with large num-
bers of pins. The temperature of the hot air is controlled elec-
tronically and is infinitely variable between 50°C and 550°C.
230 V (120 V) mains voltage is required to operate the unit.
The air flow is infinitely variable electronically within the
range of approx. 10-50 l/min and is generated by a turbine.
The hot air is activated using a finger switch or optional foot
switch. The heating element is potential-free and all-insula-
ted.

Technical Data

Dimensions:
ø 130 mm, height 220 mm
Mains voltage:
230 V (120 V)
Power consumption:
800 W (820 W)
Hot air pencil output:
700 W (730 W)
Fuse:
T 4,0A (T 10A)
Temperature control:
Infinitely variable between 50°C
and 550°C (100°F-1000°F)
Control accuracy: ± 30°C
Flow control:
Infinitely variable between 10-
50 l/min
5

3. Commissioning

Place the hot air pencil in the safety rest. Check whether the
mains voltage is consistent with the information on the type
plate. If the mains voltage is correct, connect the unit to the
mains.
Set the desired temperature on the rotary potentiometer (8)
and the air flow on the rotary potentiometer (7) and switch on
the unit at the mains switch (8).
Warning: Do not point the hot air pencil at people or
flammable objects.
The heating and standby function with reduced air quantity
are activated when the green LED (4) is flashing.
The set air flow is activated after operating the finger switch.
Heating-up timer of the nozzle depends essentially on the
size of the nozzle and the air flow.
4. Operating guidelines
Changing the nozzles
The hot air nozzles are fixed to the heating element with an
attachment screw.

5. Accessories

For nozzle range see page 21 - 26.
5 15 049 99
Nozzle changer
5 15 048 99
Multiple rest for six nozzles

6. Scope of Supply

WHA 300 control unit with hot air bit and safety rest
1 bag with: 3 cheese head screws hexagon socket M3X5
hexagon socket
Operating instructions
Safety Information
Subject to technical change without notice!

Advertisement

Table of Contents
loading

Table of Contents