The dimensions of the housing are to be chosen according to the technical drawings and a ventilation grid or
slot – with ventilation area min 150cm2 – needs to be placed near the base of the unit, minimally 200 mm
below the burner surface.
The dimensions and shape of the ventilation grid may be according to client specifications however both the minimum
ventilation area of 150 cm2 as well as minimum distance from the edge of the housing of 200 mm minimum need to
be observed.
If a hood is placed above the burner it needs to be made of non-flammable materials and a minimum distance
of 60 cm from the surface of the burner needs to be observed.
diagonal hood above the burner one needs to remember that all surfaces inside the housing exposed to
contact with hot air need to be made of non-flammable materials.
It is not permitted to use a device which is not housed in some way.

4.3 Directions of how to design a housing for the fireplace

Ventilation grate or slot with ventilation area of minimum 150cm2
Copyright Planika Sp. z o.o.
www.planikafires.com
WARNING!!!
IG0115#03
16.03.2020
If the housing is devoid of a