Wall Switch - Planika GaLiO Fire Pit Insert User And Installation Manual

G20/g25 (natural gas), g30/g31 (propane-butane/propane)
Table of Contents

Advertisement

On-Demand Pilot
This green feature eliminates gas energy consumption during extended appliance inactivity. When the appliance
is inactive for an extended period of time the system automatically extinguishes the pilot. This feature helps the
consumer realize cost benefits by automatically eliminating energy consumption during non-heating months and
limited use.
The programmed length of inactivity to activate the system is specified by the appliance manufacturer and cannot
be altered in the field.

5.5 Wall Switch

Depending on customers preferences GaLiO Fire Pit Insert may be additionally operated either by Wall Switch
(included) or Touch panel. Both can be placed maximum 8 meters away from the Insert. Additionally behind Wall
Switch the battery box can be placed.
To Turn ON Appliance
ON-OFF
Press
Once pilot ignition is confirmed, there is main gas flow.
Standby Mode (Pilot Flame)
Press and hold
Copyright Planika Sp. z o.o.
Wall Switch and Touch Panel
button until two short beeps confirm the start sequence has begun; release button.
(small flame) button to set appliance at pilot flame.
www.planikafires.com
IG0115#03
16.03.2020