Plant Loop Termination Unit
(NTPL01)
Process Control and
Automation Solutions
from Elsag Bailey Group

Advertisement

Table of Contents
loading

Summary of Contents for Bailey Infi 90 NTPL01

  • Page 1 E96-418 ® ® Plant Loop Termination Unit (NTPL01) Process Control and Automation Solutions from Elsag Bailey Group...
  • Page 2 The information contained in this document is subject to change without notice. Elsag Bailey, its affiliates, employees, and agents, and the authors and contributors to this publication specif- ically disclaim all liabilities and warranties, express and implied (including warranties of merchantability and...
  • Page 3 Preface The NTPL01 terminates the connection of Plant Loop to the Loop Interface Module (INLIM03). The NTPL01 is designed to provide isolation between the INLIM03 and the Plant Loop. It has terminals for connecting twinaxial cable and a shield. This manual explains how to install and use the NTPL01. It explains how to install the cables, mount the termination mod- ule and lists maximum cable lengths for the communication loop.
  • Page 4 ® List of Effective Pages Total number of pages in this instruction is 23, consisting of the following: Page No. Change Date Preface Original List of Effective Pages Original iii through vi Original 1-1 through 1-3 Original 2-1 through 2-5 Original Original 4-1 through 4-2...
  • Page 5 Safety Summary GENERAL Equipment Environment WARNINGS All components, whether in transportation, operation or storage, must be in a noncorrosive environment. Electrical Shock Hazard During Maintenance Disconnect power or take precautions to insure that contact with energized parts is avoided when servicing. Special Handling This module uses Electrostatic Sensitive Devices (ESD).
  • Page 6 ® Sommaire de Sécurité AVERTISSEMENTS Environnement de l’équipement D’ORDRE Ne pas soumettre les composants à une atmosphère corrosive lors GÉNÉRAL du transport, de l’entreposage ou l’utilisation. Possibilité de chocs électriques durant l’entretien Débrancher l’alimentation ou prendre les précautions pour éviter tout contact avec des composants sous tension durant l’entretien.
  • Page 7: Table Of Contents

    Table of Contents Page SECTION 1 - INTRODUCTION ....................1-1 INTRODUCTION......................1-1 INTENDED USER ......................1-1 HARDWARE DESCRIPTION..................1-2 FEATURES........................1-2 INSTRUCTION CONTENT .....................1-2 HOW TO USE THIS MANUAL ..................1-2 REFERENCE DOCUMENTS..................1-2 GLOSSARY OF TERMS AND ABBREVIATIONS .............1-3 NOMENCLATURE ......................1-3 SPECIFICATIONS ......................1-3 SECTION 2 - INSTALLATION .....................2-1 INTRODUCTION......................2-1 SPECIAL HANDLING ....................2-1 UNPACKING AND INSPECTION ..................2-1...
  • Page 8 ® List of Tables Title Page 2-1. TPL Cable Applications ..................2-3 3-1. Maintenance Schedule................... 3-1 A-1. LIM Event Counter Addresses (S1) ................. A-2 A-2. LIM Error Counter Addresses (S1) ................. A-3 A-3. PCU Address Settings (S2) ..................A-4 List of Figures Title Page 1-1.
  • Page 9: Section 1 - Introduction

    SECTION 1 - INTRODUCTION INTRODUCTION The Plant Loop Termination Unit (NTPL01) provides a termina- tion point for a Loop Interface Module (INLIM03). The TPL ter- minates a twinaxial cable when connecting the LIM to Plant Loop. The NTPL01 isolates the communication signals between Plant Loop and the INLIM03.
  • Page 10: Hardware Description

    I-E96-500 Site Planning and Preparation I-E96-506 Modular Power System I-E96-508 DC Modular Power System I-E96-605 Bus Interface Module/Loop Interface Module (INBIM02/INLIM03) ® - INFI 90 is a registered trademark of Elsag Bailey Process Automation. HARDWARE DESCRIPTION 1 - 2 I-E96-418A...
  • Page 11: Glossary Of Terms And Abbreviations

    CSA certified as process control equipment for use in an ordinary Certification (nonhazardous) location. Specifications are subject to change without notice. ® - Network 90 is a registered trademark of Elsag Bailey Process Automation. GLOSSARY OF TERMS AND ABBREVIATIONS I-E96-418A 1 - 3...
  • Page 12: Section 2 - Installation

    SPECIAL HANDLING Observe these steps when handling electronic circuitry: NOTE: Always use Bailey's Field Static Kit (P/N 1948385A1 - con- sisting of wrist straps, ground cord assembly, and alligator clip) when working with the modules. The kit connects a technician and the static dissipative work surface to the same ground point to pre- vent damage to the modules by electrostatic discharge.
  • Page 13: Installing The Termination Unit

    INSTALLATION ® 3. File a claim for any damage with the transportation com- pany that handled the shipment. 4. Use the original packing material or container to store the termination module. 5. Store the module in an environment of good air quality, free from temperature and moisture extremes.
  • Page 14: Cable Installation

    INSTALLATION 3. Connect the chassis ground by installing a number ten self tapping screw and external star washer in the location shown in Figure 2-1. CABLE INSTALLATION Termination Unit Cables After mounting the termination unit to the FTP, install the ter- mination cables.
  • Page 15: Communication Cable

    INSTALLATION ® Communication Cable The communication cable connects the TPL to Plant Loop. Table contains information about the connector assign- ments and length restrictions of the communication cable. To install the communication cable, connect the cable to the ter- mination unit at the terminal blocks, TB1 or TB2. Figure shows the TPL terminal assignments.
  • Page 16: Power Wiring

    INSTALLATION POWER WIRING We strongly recommend that you turn cabinet power off before doing any termination unit wiring. Failure to do so could result CAUTION in equipment damage. Do not apply power until you verify all wire connections. Il est fortement recommande, de debrancher l'alimentation electrique du cabinet avant d'effectuer toute connexion aux cartes de raccordement du chassis.
  • Page 17: Section 3 - Maintenance

    SECTION 3 - MAINTENANCE INTRODUCTION The plant loop termination unit requires minimal mainte- nance. Doing the tasks in Table will provide long, trouble free service. Please note that only qualified personnel should perform maintenance. MAINTENANCE SCHEDULE Table is the maintenance schedule. These tasks are to be performed at the specified intervals.
  • Page 18: Section 4 - Repair/Replacement Procedures

    SECTION 4 - REPAIR/REPLACEMENT PROCEDURES INTRODUCTION Repair procedures are limited to termination unit (TU) replace- ment. If the TPL fails, remove it and replace it with another one. TERMINATION UNIT REPLACEMENT If you determine that the TPL is faulty, replace it with a new one.
  • Page 19 REPAIR/REPLACEMENT PROCEDURES ® 5. Remove the faulty termination unit. 6. Insert the tabs of the replacement TU into the same slots of the termination panel standoff as shown in Figure slide the circuit board into position. 7. Secure the termination unit circuit board to the field termi- nation panel and replace the chassis ground with the screws saved from step 4.
  • Page 20: Section 5 - Support Services

    SECTION 5 - SUPPORT SERVICES INTRODUCTION Bailey Controls is ready to help in the use and repair of its products. Contact your nearest sales office to make requests for sales, applications, installation, repair, overhaul and main- tenance contract services. REPLACEMENT PARTS AND ORDERING INFORMATION When making repairs at your facility, order replacement parts from a Bailey sales office.
  • Page 21 Index Cable lengths ............. 2-3 NFTP01...............1-3 Nomenclature..............1-3 Documentation ............5-1 Ordering information ...........5-1 Glossary of terms and abbreviations ......1-3 Plant loop ..............1-3 Hardware description ..........1-2 Reference documents..........1-2 Repair procedure ............4-1 Installation Communication cable ........... 2-4 Power wiring ............2-5 Special handling............2-1 Termination unit ............
  • Page 22 Telefax 39-10-6582-941 Telephone 49-69-799-0 Telefax 65-292-9011 Telefax 49-69-799-2406 Form I-E96-418A Litho in U.S.A. 592 Copyright © 1992 by Elsag Bailey Process Automation, As An Unpublished Work ® Registered Trademark of Elsag Bailey Process Automation ™ Trademark of Elsag Bailey Process Automation...