Page 1
E96-406 ® ® Analog Master Termination Unit (NTAM01) Process Control and Automation Solutions from Elsag Bailey Group...
Page 2
The information contained in this document is subject to change without notice. Elsag Bailey, its affiliates, employees, and agents, and the authors and contributors to this publication specif- ically disclaim all liabilities and warranties, express and implied (including warranties of merchantability and...
Page 3
This manual explains how to install and use the NTAM01 unit on the INFI 90 system. It has sections that describe the setup and cabling. The appendix contains information about the IMAMM03 module. ® INFI 90 is a registered trademark of Elsag Bailey Process Automation. I-E96-406A...
Page 4
® List of Effective Pages Total number of pages in this manual is 26, consisting of the following: Page No. Change Date Preface Original List of Effective Pages Original iii through vi Original 1-1 through 1-5 Original 2-1 through 2-7 Original Original 4-1 through 4-2...
Page 5
Safety Summary GENERAL Equipment Environment WARNINGS All components, whether in transportation, operation or storage, must be in a noncorrosive environment. Electrical Shock Hazard During Maintenance Disconnect power or take precautions to insure that contact with energized parts is avoided when servicing. SPECIFIC Remove modules from their module mounting unit slots before CAUTIONS...
Page 6
® Sommaire de Sécurité AVERTISSEMENTS Environnement de l’équipement D’ORDRE Ne pas soumettre les composants à une atmosphère corrosive lors GÉNÉRAL du transport, de l’entreposage ou l’utilisation. Possibilité de chocs électriques durant l’entretien Débrancher l’alimentation ou prendre les précautions pour éviter tout contact avec des composants sous tension durant l’entretien.
Table of Contents Page SECTION 1 - INTRODUCTION ....................1-1 OVERVIEW ........................1-1 INTENDED USER ......................1-1 UNIT DESCRIPTION .....................1-1 FEATURES........................1-1 INSTRUCTION CONTENT .....................1-3 HOW TO USE THIS MANUAL ..................1-3 GLOSSARY OF TERMS AND ABBREVIATIONS .............1-3 NOMENCLATURE ......................1-4 REFERENCE DOCUMENTS..................1-5 SPECIFICATIONS ......................1-5 SECTION 2 - INSTALLATION .....................2-1 INTRODUCTION......................2-1 SPECIAL HANDLING ....................2-1 UNPACKING AND INSPECTION ..................2-2...
Page 8
® List of Figures Title Page 1-1. Application Example for NTAM01 Unit ..............1-2 2-1. Installation for Termination Unit ................2-3 2-2. Cable Connections for NTAM01 Unit ..............2-4 2-3. Cable Connector Locations for NTAM01 Unit ............2-5 A-1. IMAMM03 Address Select Switch (SW2) ..............A-2 B-1.
SECTION 1 - INTRODUCTION OVERVIEW The NTAM01 Analog Master Termination Unit is only required for redundant IMAMM03 Analog Master Modules using ther- mocouple slaves or to connect digital indicator stations. The NTAM01 unit can connect up to four NTAI02 units and up to four indicator stations.
INTRODUCTION ® COMMUNICATION HIGHWAY (INFI-NET OR PLANT LOOP) COMMUNICATION MODULES MODULE BUS IMAMM03 IMAMM03 OTHER MODULES SLAVE EXPANDER BUS IMASM02 NTAM01 IMASM02 OTHER ANALOG SLAVE MODULES NTAI02 NDIS01 NTAI02 ANALOG INPUTS ANALOG INPUTS T00472A Figure 1-1. Application Example for NTAM01 Unit A standard factory-wired cable connApplication Example for •...
Repair/Replacement Details how to replace a termination unit. Procedures Support Services Describes the support services (repair parts, training, docu- mentation, etc.) available from Bailey Controls Company. Appendix A Shows the switch settings for the IMAMM03 Analog Master Module. Appendix B Shows the switch and jumper settings for the NDIS01 Digital Indicator Station.
Cable, IMAMM03 module to NTAM01 unit (PVC) NKTU11 Cable, IMAMM03 module to NTAM01 unit (non-PVC) NTAI02 Termination unit/thermocouple input NTFP01 Field termination panel ® Network 90 is a registered trademark of Elsag Bailey Process Automation. NOMENCLATURE 1 - 4 I-E96-406A...
Atmospheric Pressure Sea level to 3 km (1.86 mi) Air Quality Noncorrosive No cooling is necessary when used in Bailey Controls cabinets and Cooling Requirements operated within stated limits. Certification CSA certified for use as process control equipment in an ordinary (non- hazardous) location.
SPECIAL HANDLING Observe these steps when handling electronic circuitry: NOTE: Always use the Bailey Controls Field Static Kit (part number 1948385A1 - consisting of two wrist straps, ground cord assembly, alligator clip, and static dissipating work surface) when working with modules.
These are steps to follow for general handling: 1. Examine the unit to make sure that no damage has occurred in transit. 2. Notify the nearest Bailey Controls sales office of any dam- age. 3. File a claim for any damage with the shipping company that handled the shipment.
INSTALLATION TABS STANDOFF MOUNTING SCREWS FIELD TERMINATION PANEL T00473A Figure 2-1. Installation for Termination Unit An NKDS01 and NKDS11 cable connects P4 to a single NDIS01 Digital Indicator Station. Connect the cable to the left hand connector on the housing as viewed from the rear. An NKDS02 and NKDS12, and NKDS03 and NKDS13 cables connects P4 to multiple NDIS01 Digital Indicator Stations.
INSTALLATION ® NIDS01 NKAI01/11 NKTU01/11 IMAMM03 NDIS01 (PRIMARY) NKTU01/11 NTAM01 NKTU01/11 NKDS02/12 OR NKDS01/11 FOR A SINGLE NIDS01 NKAI01/11 IMAMM03 NTAI02 (REDUNDANT) PAIR A TO P4 ON NEXT INTERCONNECTED NTAI02. TO RTD PAIR B THROUGH RTD PAIR D IF REQUIRED. IMASM02 NOTES: 1.
INSTALLATION Table 2-1. NTAM01 Cable Applications (continued) Maximum Cable Application Connector Length NKDS02 (PVC) Connects NTAM01 unit to the first P4 on NTAM01 unit to P1 69 m NDIS01 station of up to four sta- NDIS01 station (225 ft) NKDS12 (non-PVC) tions NKDS03 (PVC) Connects second, third or fourth...
Page 19
INSTALLATION ® To install the cables follow these steps. 1. Pull the master modules several inches from the MMU backplane. Remove modules from their module mounting unit slots before CAUTION installing or removing a cable assigned to that slot. Failure to do so could result in damage to the module.
INSTALLATION with an NKDS02 or NKDS12 cable. Connect the J1 end of the NKDS02 or NKDS12 cable to P4 of the termination unit and the J2 end of the NKDS02 or NKDS12 cable to the left slot on the station housing (P1 of the NDIS01 station). A total of four NDIS01 modules can be added by connecting the J3 end of the NKDS02 or NKDS12, or NKDS03 or NKDS13 cables to the J1 end of an NKDS03 or NKDS13 cable.
SECTION 3 - MAINTENANCE INTRODUCTION The NTAM01 Analog Master Termination Unit requires limited maintenance. This section contains a maintenance schedule. MAINTENANCE SCHEDULE Execute the tasks in Table at the specified intervals. Table 3-1. Maintenance Schedule Task Interval Clean and tighten all power and Every 6 months or during plant shut- grounding connections.
SECTION 4 - REPAIR/REPLACEMENT PROCEDURES INTRODUCTION This section explains the replacement procedures for the NTAM01 Analog Master Termination Unit. No special tools are required to replace the module. REPLACEMENT PROCEDURES If an NTAM01 unit is faulty, replace it with a new one. Do not try to repair the module.
Page 23
REPAIR/REPLACEMENT PROCEDURES ® 4. Label and disconnect system I/O power and ground wires from the terminals. 5. Remove the two number 10 screws securing the termina- tion unit to the field termination panel. 6. Insert the tabs of the replacement circuit board into the proper slots of the field termination panel stand-off and slide the circuit board into position.
SECTION 5 - SUPPORT SERVICES INTRODUCTION Bailey Controls Company is ready to help in the use, applica- tion and repair of its products. Contact the nearest sales office to make requests for sales, applications, installation, repair, overhaul and maintenance contract services.
APPENDIX A - IMAMM03 ANALOG MASTER MODULE INTRODUCTION The IMAMM03 Analog Master Module uses an NTAM01 unit for termination when running redundant IMAMM03 modules or to run NDSI01 indicator stations. Each NTAM01 unit accepts up to four NTAI02 units. This appendix contains fig- ures and tables that show the dipswitch location on the IMAMM03 module and its settings.
IMAMM03 ANALOG MASTER MODULE ® MODULE STATUS LED MODE LED GROUP OPEN RESET HARDWARE CONFIGURATION SWITCH S1 SWITCH S2 T00475A Figure A-1. IMAMM03 Address Select Switch (SW2) INTRODUCTION A - 2 I-E96-406A...
APPENDIX B - NDIS01 DIGITAL INDICATOR STATION INTRODUCTION The NDIS01 Digital Indicator Station uses an NTAM01 unit for termination to an IMAMM03 master module. This appendix contains the dipswitch location on the NDIS01 station and intensity jumpers and their settings. This information is pro- vided as a quick reference guide for personnel installing the NTAM01 unit.
Page 28
Index Analog master module (IMAMM03)......A-1 NDIS01 address select switch (SW1) ......B-1 Application example for NTAM01 unit ......1-2 Nomenclature..............1-4 NTAM01 cable applications ........2-4 Cable connections for NTAM01 unit......2-4 Overview ..............1-1 Digital indicator station (NDIS01) ....... B-1 Reference documents..........1-5 Repair/replacement procedures........4-1 Replacement parts and ordering information....5-1 Features ..............