VLT® Micro Drive FC 51
Operating Guide
Number
Description
51
AMA check U
nom
I
nom
52
AMA low I
nom
59
Current limit
63
Mechanical brake low
80
Drive initialized to de-
fault value
84
The connection be-
tween drive and LCP is
lost
85
Key disabled
86
Copy fail
87
LCP data invalid
88
LCP data not compati-
ble
89
Parameter read only
90
Parameter database
busy
91
Parameter value is not
valid in this mode
92
Parameter value ex-
ceeds the minimum/
maximum limits
nw run
Not while running
Err.
A wrong password was
entered
These faults are caused by mains distortions. Install a Danfoss line filter to rectify this problem.
1
Danfoss A/S © 2020.09
Warn-
Alarm
ing
and
X
X
X
X
X
Trip
Er-
Cause of problem
lock
ror
Wrong setting for motor voltage and/or motor current.
The motor current is too low. Check the settings.
The drive overload.
Actual motor current has not exceeded the release
brake current within the start delay time window.
All parameter settings are initialized to default settings.
X
No communication between LCP and drive.
X
See parameter group 0-4* LCP.
X
An error occurred while copying from drive to LCP, or
from LCP to drive.
X
Occurs when copying from LCP if the LCP contains er-
roneous data - or if no data was uploaded to the LCP.
X
Occurs when copying from LCP if data are moved be-
tween drives with major differences in software ver-
sions.
X
Occurs when trying to write to a read-only parameter.
X
LCP and RS485 connection are trying to update param-
eters simultaneously.
X
Occurs when trying to write an illegal value to a param-
eter.
X
Occurs when trying to set a value outside the range.
X
Parameters can only be changed when the motor is
stopped.
X
Occurs when using a wrong password for changing a
password-protected parameter.
Troubleshooting
AQ348848915086en-000101 / 130R0943 | 25