Option and peripheral devices

Option List
Name
CC-Link communication
Parameter unit
(8 languages)
Parameter unit with battery
pack
Parameter unit connection
cable
Operation panel connection
connector
Heatsink protrusion
attachment
Radio noise filter
Line noise filter
Peripheral devices/cable size list
cable size

200V class
FR-HC2-
Model
R4/L14, S4/L24,
T4/L34
7.5K
8
15K
22
30K
60
55K
100
75K
100
400V class
FR-HC2-
Model
R4/L14, S4/L24,
T4/L34
H7.5K
3.5
H15K
5.5
H30K
22
H55K
60
H75K
38
H110K
60
H160K
100
H220K
150
H280K
200
2 200
H400K
2 250
H560K

For the 55K or lower, the cable size is that of the cable (HIV cable (600V class 2 vinyl-insulated cable) etc.) with continuous maximum permissible
temperature of 75C. It assumes that the surrounding air temperature is 50C or less and the wiring distance is 20m or less.
For the 75K or higher, the recommended cable size is that of the cable (LMFC (heat resistant flexible cross-linked polyethylene insulated cable) etc.) with
continuous maximum permissible temperature of 90C. It assumes that the surrounding air temperature is 50C or less and wiring is performed in an
enclosure.

If a cable thinner than the recommended cable size is used, it may not be protected by the DC fuse. (Refer to page 28 for the fuse selection.)
26
Type
Converter operation, monitoring, and parameter setting can be
FR-A7NC
commanded from a programmable controller.
FR-PU07
Interactive parameter unit with LCD display
Parameter unit enables parameter setting without supplying power
FR-PU07BB
to the converter.
Cable for connection of operation panel or parameter unit
FR-CB20
indicates a cable length. (1m, 3m, 5m)
Connector to connect the operation panel (FR-DU07-CNV) and
FR-ADP
connection cable
FR-A7CN
Attachment for protruding the converter heatsink at the back of the
02 to 05, 09
enclosure. Refer to page 17 for the enclosure cut dimensions.
FR-BIF(H)
For radio noise reduction (connect to the input side)
FR-BSF01/
For line noise reduction
FR-BLF
FR-HCB2-
P/+, N/-
R2/L12, S2/L22, T2/L32

R3/L13, S3/L23, T3/L33
5.5
8
14
22
38
60
100
100
100
100
FR-HCB2/FR-HCC2-
P/+, N/-
R2/L12, S2/L22, T2/L32

R3/L13, S3/L23, T3/L33
2
3.5
5.5
5.5
14
22
38
60
38
38
60
60
125
100
2 100
150
2 125
60
2 200
60
3 250
38
Applications, Specifications, etc.
FR-HCL21-
R/L1, S/L2, T/L3
R2/L12, S2/L22, T2/L32
8
22
60
100
100
FR-HCL21-
R/L1, S/L2, T/L3
R2/L12, S2/L22, T2/L32
3.5
5.5
22
60
38
60
100
150
200
2 200
2 250
Applicable
converter
Shared among
all models
Shared among
all models
Shared among
all models
Shared among
all models
Shared among
all models
According to
capacities
Shared
among
all models
Shared
among
all models
FR-HCL22-
R3/L13, S3/L23, T3/L33
R4/L14, S4/L24, T4/L34
8
22
60
100
100
FR-HCL22-
R3/L13, S3/L23, T3/L33
R4/L14, S4/L24, T4/L34
3.5
5.5
22
60
38
60
100
150
200
2 200
2 250

Advertisement