Download Print this page

Panasonic Tro-Reel 60A Operation Manual page 23

For indoor and outdoor use

Advertisement

■ Center fixed insulator
1.Mount center fixed insulators to
hangers (shown above).
2.Attach the insulator to the Tro-Reel
unit. Drill a φ5mm hole. Insert a
knock pin and fit on the cover.
Notes
When using hangers with insulators, be
sure to mount two fo them.
 Failure to do so may cause damage due to
falling of equipment.
Be sure to use a file of φ5 size.
 Otherwise, falling may occur.
In the case of a porcelain insulator hanger
with it, Please contact Pansonic Electric
Works Co.,Ltd.
Mount the cover by all means.
 Failure to do so may cause electric shock.
■  Joiner
To connect Tro-Reel units together.
60A・150A
● 
1.Cut 40mm off of each end of the insulating
sheath.
 Cut the insulating sheath completely off
the recess on the side.
2.Sandwichthe conductor between joiner
terminals. Tighten the bolts with a hex
wrench tight [Setting Torque 6.9〜7.9N・
m]. Failure to do so may cause poor
collector arm contact or damage due to
falling of equipment.
3.Fit on a Sheath repair cover .
 Apply the insulator along the center line 
 of the insulating sheath cutaway.
 200A and 300A
1.Cut 40mm off of each end of the insulating
sheath.
 Cut the insulating sheath completely off
the recess on the side.
2.Connect the conductors with the terminal
plates and drill
 φ5mm boles in the conductors.Insert
knock pins through the holes.
3.Fit on a Sheath repair cover .
 Apply the insulator along the center line of
the insulating sheath cutaway.
Notes
Be sure to use a file of φ5 size.
 Failure to do so may cause poor
collector arm contact or damage due to
falling of equipment.
This part is to be used in horizontal curves, and should be attached at the joint between straight and curved sections to apply tension in the straight section.
Joiner terminal
Tro-Reel unit
Terminal plate
φ5mm drill bit
ー 26 ー
Cover
φ5mm knock pin
Center fixed
insulator bracket
Center fixed
insulator
Close together
Joiner terminal
hex wrench
(not included)
Tro-Reel unit
φ 5mm knock pin
Drill
Center fixed
insulator bracket
Hanger
-100×50×5
46mm
Hanger with
insulator
Tension
Bolt
Cover
Nut
Cover screw
Joiner cover
Cover screw

Advertisement