How to mount collector arms
9
■Standard installation
Tro-Reel unit
Collector arm mount rod, 25×25mm
(not included)
Set the distance from the bottom surface of the Tro-reel conductor to the
●
center ofthe collector arm mount rod (not included) to 95mm (in the
center of the conductor cleraner mounting tolerance movable range
95±20mm)
Arm must be attached parallel to the Tro-Reel unit without any twisting.
●
Use range of movable
When collector arm mount rod set up a reference position,
the operating range from 70mm 〜 110mm of collector arm set up to be twisting.
Adjust the arm mount rod between the High-Tro-Reel unit to become 110mm
or less and 70mm or more at the center between hangers, and 70mm or more
at the bracket.
■Assembly in tandem configuration
Two collector arms should be used together (tandem type) for circuit
●
separation and line swiching, and especially in applications in which it is
imperative that collector arms not be separated from wires. Tandem
collector arms cannot be used horizontally. For horizontal installations,
use a single-type collector arm.
Bolt
Bolt
■Collector shoe replacement
Collector shoes should be replaced when they
●
partially wear down to the replacement indication line.
Please exchange the collector shoes ahead of time
when it will be worn out to the replacement indication
line by the time of the next check.
Notes
After installation, be sure that the hanger, the Tro-Reel unit and the collector arm are level. Failure to do so may
●
cause poor collector arm contact.
When you want to use the collector arms with centerring horizontally,please contact Panasonic electric Works,Ltd.
●
In a horizontal ways case, be sure to use the horizontal support parts.
●
Failure,there is a risk of derailment or loose arms collector.
Distance to the center of the collector arm from the center of the duct
●
Collector arm
Collector arm mount rod
Replacement line
Collector shoe
Push here.
■Horizontal installation
Base
Collector arm support
parts for transverse
Fixing screw
(M4×8)
As shown in a figure,mounted collector arm support parts for transverse
●
on base of the collector arm.
Tightening torque of fixing screws:0.98 N・m〜1.32 N・m
Set the distance from the bottom surface of the Tro-reel conductor to the
●
center ofthe collector arm mount rod (not included) to 95mm (in the center
of the conductor cleraner mounting tolerance movable range 95±20mm)
Distance to the center of the collector arm
from the center of the duct
Distance to the center of the collector arm
from the center of the duct
Not use the horizontal support parts
Use the horizontal support parts
■Horizontal installation with its opening
facing into tandem-type
Mounting the horizontal support parts in both the collector arms
●
Collector arm
support parts
for transverse
■ Wire clamp
Give slack to a lead.(Lead is a fixed position,
430mm from the base of collector)
Do not affect a collector's run.
Collector arm
Cable clamp
ー 30 ー
Tro-Reel unit
Collector arm
Collector arm
mount rod
(not included)
Dimension A of permitted
movable range
A
A
15mm
5mm
Bolt
Collector arm
support parts
Bolt
for transverse
Fixing screw
430mm
Lead