■ Intermediate tension insulator
Mounting an insulator on a bracket
●  
Mount the intermediate tension insulator to
the intermediate tension insulator bracket
using nuts A and B.
Intermediate tension
Bracket when using a
standard hanger
insulator bracket
13mm or less
Connection to Tro-Reel
●  
1. Loosen the intermediate tensioninsulator nuts. Set the distance between the intermediate tension insulator and the intermediate tension insulator bracket to 150mm.
2. Connect the intermediate tension insulator A and the Tro-Reel unit with a center feed-in joiner.
(a)
Crimp-on terminal
(Accompanying)
Bypass wire
Terminal
plate
 For steps (a), (b) and (c), please follow the center feed-in
  joiner mounting procedure in Section
3. Temporarily fix the Tro-Reel unit to the hangers in order
 starting from the intermediate tension insulator side.
< 300A >
Terminal plate
(a)
Tro-Reel unit
Bypass wire
Crimp-on terminal
<not included>
Caution
Applying tension to the Tro-Reel unit
●  
1.To take up the sag of the Tro-Reel
unit, tighten the tension bolt nus
until the coil spring is the length
indicated below.
2.Please install a center fixed
insulator in being making the
space become to 15mm ± 5mm.
Coil spring length
●  
Ambient temperature during installation
10
or lower
11〜40
Applies tension to a straight line of more than 100m or to an endless line, and absorbs expansion and contraction in the Tro-Reel unit due to temperature fluctuation.
Bracket when using a hanger
with an insulator
On-site assembly
<60A and 150A and 200A>
Intermediate tension
insulator bracket
B
150mm
Intermediate tension insulator
(b)
Insulating sheath
Terminal plate
Bypass wire
8
.
(b)
Terminal plate
Bypass wire
Hex key wrench
<not included>
Terminal screws must be securely tightened.
Failure to do so may cause fire.
Bypass
Tension
B
Tension section (tension applied by coil spring)
Notes
L
Set the gap to 15mm ± 5mm regardless of ambient temperature.
115mm
If using intermediate tension insulator, a center fixed insulator is also necessary.
 Failure to do so may cause poor collector arm contact or separation from wires.
125mm
150mm
75mm
Nut B
Nut A
1.5m or less
Nut
Bypass wire
Center feed-in joiner
A
Tro-Reel unit
φ 5mm
knock pin
φ 5mm drill bit
Drill
Notes
Be sure to use a file of φ5 size.
Terminal screws and φ5mm knock pins must be securely tightened. (tightening torque 6.9〜7.9N・m)
Failure to do so may cause poor collector arm contact or damage due to falling of equipment.
Tro-Reel unit
(c)
φ 5mm knock pin
Bypass wire
φ 5mm
drill bit
Drill
Notes
Be sure to use a file of φ5 size.
The φ5mm knock pins must be securely fitted.
Failure to do so may cause damage due to falling of equipment.
1.5m or less
M12 tension bolt Coil spring
L
Nut
A
Gap
(15mm)
ー 27 ー
900〜930mm
bolt (M12)
Bypass wire
4m or less
Mounting
direction
Tro-Reel unit
(c)
Feed-in cover
Cover screw
Cover screw
0.5m
Intermediate tension insulator bracket
Center fixed insulator bracket
Center fixed insulator
Tro-Reel
Intermediate
unit B
To be measured and
tension insulator
cut on-side
No tension section
Center feed-in.
joiner
On-site assembly
Feed-in cover
4m or less
Tro-Reel unit