Provisions And Regulations; Installation Location; Preparing For Unit Installation; Water Connection - STIEBEL ELTRON DHF 13 C compact control Operating And Installation

Hydraulically controlled instantaneous water heater
Hide thumbs Also See for DHF 13 C compact control:
Table of Contents

Advertisement

instAllAtion
instAllAtion
— One-hand mixer and thermostatic fittings must be suitable for
hydraulically controlled instantaneous water heaters.
— Practical hints:
So that the switch-on quantities (see Table 3) of stage • and stage
• • are safely reached, the pressure loses of the instantaneous
water heater, fitting, hand-held shower, shower hose and the pipe
network must be taken into account upon installation.
Typical pressure loss values for a shower water quantity of approx.
10 l/min:
— one-hand mixer
0.04 - 0.08 MPa
— thermostatic fittings 0.03 - 0.05 MPa
— hand-held shower
0.03 - 0.15 MPa
7.4

Provisions and regulations

— Installation (water and electrical installation), as well as
the first start-up and maintenance of this unit, may only be
carried out by a qualified installer in accordance with these
instructions.
— Faultless operation and operational safety are only guaran-
teed if the original accessories and spare parts intended for
the unit are used.
— Regulations of the local energy supply company.
— Regulations of the relevant water supply company.
— Notice for Australia / New Zealand:
The installation shall comply with AS/NZS 3500.4.
— Install the unit flush with the wall at the lower end (18,
observe dimension ≥ 110 mm).
the following should also be observed:
— The unit rating plate.
— Technical data.
water installation:
cold water line
Permissible materials: Galvanised steel pipe, stainless steel pipe,
copper pipe or plastic pipe.
Plastic piping systems
For the cold water unit connection a metal pipe of approx. 1 m long
must be installed.
dHw line
Permissible materials: Stainless steel pipe or copper pipe.
Plastic piping systems
— The DHF ... C is not suitable for installation with plastic piping
systems for the hot water pipe!
— A safety valve is not necessary.
— Operation with pre-heated water is not permitted!
— Thermostatic tap fittings - see "Adjustment recommendation".
electrical installation
— Electrical connection only to permanently-installed cables.
20
|DHF C
— It must be possible to isolate the unit from the main supply
on all poles with an isolating distance of at least 3 mm, for
example using fuses.
7.5

installation location

The DHF ... C compact control is to be installed
!
vertically in accordance with
sink) in a closed, frost-free room, as near as possible
to the tap point (a dismantled unit is to be stored
in frost-free conditions, since residual water always
remains in the unit).
7.6

Preparing for unit installation

B
Turn locking cap (3) to the left and withdraw.
»
Unscrew cover securing screw and remove device cover.
»
Detach mounting bracket (19) from the unit.
»
Thoroughly flush through the cold water supply pipe.
»
In the case of a replacement installation, the available cold water
»
3-way three-way isolating valve (
With the help of the template (separate this from the operating
»
and installation instructions), determine the position of the cable
entry (concealed connection) and the mounting bracket (19).
a
Cut the electrical connection cable to length and strip.
»
c
Secure the mounting bracket.
»
When replacing DHF/DHA old models (height 370 mm), the
»
available drilled securing holes (20) can be used.
Secure the unit to mounting bracket with the screwed sleeve
»
(14). Using the nut on the threaded bolt (21), unevennesses in
the wall, caused for example by misaligned tiles, can be com-
pensated for (maximum 12 mm).
7.7

water connection

Install the supplied parts. Note the direction arrows of the water
»
d
e
installation (
-
).
the three-way isolating valve (6) must not be used to restrict
the flow rate!
d
concealed connection
e
surface-type connection
The IP25 protection mode (hose-proof) is guaranteed
!
in the case of the following connection.
With a Stiebel Eltron surface-type tap fitting WKMD or WBMD
1
(see "Special Accessories"):
2
3
— Use water plugs G ½ (23). Water plugs fall within the scope of
4
supply of the Stiebel Eltron WKMD and WBMD fittings.
5
— In the case of third party tap fittings, the special accessory
6
module with 2 water plugs (see "Special accessories") is
7
required.
8
1
9
In the case of surface-type installation (see "Special accesso-
2
10
ries"):
3
11
4
1. Use water plugs G ½ (23).
»
12
5
13
6
14
7
15
a
(over-sink or under-
d
, 6) can if necessary be used.