Ack Nak Timeout Value - Datalogic Gryphon GD4200 Product Reference Manual

General purpose linear bar code reader: corded or with bluetooth wireless technology or datalogic’s star cordless system
Hide thumbs Also See for Gryphon GD4200:
Table of Contents

Advertisement

REFERENCES

ACK NAK Timeout Value

This option specifies the amount of time the scanner waits for an ACK character from
the host following label transmission. The selectable timeout range is 200 milliseconds
to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout.
To set this value:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
4. Scan the bar code: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See the table below for examples of how to set this fea-
ture.
Table 8 - ACK NAK Timeout Value Setting Examples
STEP
1
Desired Setting
2
Divide by 200
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ACK NAK TIMEOUT VALUE SETTING
Scan two characters from
5
Appendix D
6
Scan ENTER/EXIT PROGRAMMING MODE
224
GRYPHON™ I GD/GBT/GM4200
with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
Mode.
duration which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
NOTE: If you make a mistake before the last character, scan the CANCEL
bar code to abort and not save the entry string. You can then start again at
the beginning.
ACTION
200ms
'0' and '1'
EXAMPLES
1,000ms (1 sec.) 5200ms (5.2 sec.)
01
05
'0' and '5'
, that represent the
Appendix D
15,000ms (15 sec.)
26
75
'2' and '6'
'7' AND '5'