Thermistor Assy - Daikin RKH35QRV16 Service Manual

2.5/3.5 kw class outdoor unit cooling only
Table of Contents

Advertisement

Thermistor ASSY

4. Thermistor ASSY
Warning
Step
1
Release the discharge
pipe thermistor.
2
Cut the clamp.
3
Pull out the outdoor
heat exchanger
thermistor.
4
Remove the thermistor
ASSY.
8
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Discharge pipe
thermistor
Thermistor ASSY
Be careful not to lose the
fixture for the thermistor.
(R20278)
The positions of the clamp
and outdoor heat exchanger
thermistor vary depending
on the model.
Be careful not to lose the clip
for the thermistor.
Clamp
Outdoor heat
exchanger
thermistor
(R20279)
(R23490)
Si001407EB
Points
Fixture
(R20430)
Clip
(R3264)
Removal Procedure

Hide quick links: