Thermistor Assy - Daikin RKS22MVLT Removal Procedure

Table of Contents

Advertisement

Si001354EA

7. Thermistor ASSY

Warning
Step
1
Release the discharge
pipe thermistor.
2
Cut the clamp.
3
Pull out the outdoor
heat exchanger
thermistor and remove
the thermistor ASSY.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Discharge pipe thermistor
Outdoor heat exchanger thermistor
Be careful not to lose the
fixture for the thermistor.
(R12619)
The position of the clamp
and outdoor heat exchanger
thermistor varies by model.
Clamp
(R22512)
Be careful not to lose the clip
for the thermistor.
Thermistor
ASSY
(R22513)
Thermistor ASSY
Points
Fixture
(R18949)
Clip
(R3264)
15