Download Print this page
ADTRAN NetVanta 1748F Series Quick Start

ADTRAN NetVanta 1748F Series Quick Start

Hide thumbs Also See for NetVanta 1748F Series:

Advertisement

Quick Links

NetVanta 1748F
1700558F1#MC
1. Unpack the Switch and Check Contents
Rack Mounting Kit—Contains two brackets and eight
screws for attaching the brackets to the switch.
Power Cord
Console Cable—RJ-45 to DB-9
Documentation—Quick Start Guide
2. Mount the Switch
1
Attach the brackets to the switch.
2
Use the screws supplied with the rack to secure the switch in
the rack.
4. Connect Power
1
2
1
The switch is shipped with two universal AC power modules
installed.
2
Connect an external AC power source to the modules.
5. Verify Switch Operation
1
1
Verify basic switch operation by checking the system LEDs.
When operating normally, the PSU1/PSU2, Diag, and Fan
LEDs should all be on green.
Support - Phone: 888-423-8726
Copyright © 2016 ADTRAN, Inc. All Rights Reserved.
NetVanta 1748F
1
2
6. Perform Initial Con guration
1
1
At this point you may need to make a few basic switch
con guration changes before connecting to the network.
Connect a PC to the switch console port using the included
console cable.
2
Con gure the PC's serial port: 115200 bps, 8 characters, no
parity, one stop bit, 8 data bits, and no ow control.
3
Log in to the command-line interface (CLI) using default
settings: User "admin" with no password.
Hardware Speci cations
Chassis Speci cations
Size
438.4-mm W x 473-mm D x 43.4-mm H
17.26-inch W x 18.62-inch D x 1.71-inch H
Weight
8.395 kg (18.51 lb), with two installed power supply
modules
Temperature
Operating: 0°C to 40°C (32°F to 104°F)
Storage: -40°C to 70°C (-40°F to 158°F)
Humidity
Operating: Up to 95percent, noncondensing
Power Supply Speci cations
AC Input
100 to 240 VAC, 50/60 Hz
Maximum
6 A at 100 VAC
Current
3 A at 240 VAC
5 VDC at 3 A
DC Output
12 VDC at 33 A
Power Supply
100 to 240 VAC, 50/60 Hz, auto-sensing; hot pluggable
400 W at 240 V/100 V per module
Power
165 W maximum
Consumption
Size
54.5-mm W x 220-mm D x 40.25-mm H
(2.15-inch W x 8.66-inch D x 1.58-inch H)
Regulatory Compliances
Emissions
EN 55022:2010 Class A
EN 61000-3-2:2009 Class A
EN 61000-3-3:2008
FCC Class A
VCCI Class A
CE Mark
Immunity
EN 55024:2010
ICE 61000-4-2/3/4/5/6/8/11
Safety
UL (CSA 22.2 No 60950-1 and UL 60950-1)
CB (IEC/EN 60950-1)
– 1 –
2
3
61700558F1MC-13A
January 2016

Advertisement

loading

Summary of Contents for ADTRAN NetVanta 1748F Series

  • Page 1 When operating normally, the PSU1/PSU2, Diag, and Fan Safety UL (CSA 22.2 No 60950-1 and UL 60950-1) LEDs should all be on green. CB (IEC/EN 60950-1) Support - Phone: 888-423-8726 61700558F1MC-13A – 1 – Copyright © 2016 ADTRAN, Inc. All Rights Reserved. January 2016...
  • Page 2 UL 60950-1. The conditions are only maintained if the mounting screws. equipment to which it is connected also operates under SELV conditions. Support - Phone: 888-423-8726 61700558F1MC-13A – 2 – Copyright © 2016 ADTRAN, Inc. All Rights Reserved. January 2016...

This manual is also suitable for:

Netvanta 1748f-mc1700558f1