Download Print this page

Heating Capacity Table; Model: Woyg160Ljl - Fujitsu Super High Power Series Design & Technical Manual

Split type
Hide thumbs

Advertisement

Table of Contents

7. Heating capacity table

• FT: Flow temperature
• OT: Outdoor temperature
• HC: Heating capacity (kW)
• IP: Input power (kW)
• COP: Coefficient Of Performance
• Usage environment, such as operation of the heating equipment, room temperature, and control
adjustments may cause disparities between practically determined and measured values.

7-1. Model: WOYG160LJL

FT
30°C
OT
HC
IP
COP
-25°C
8.18
4.09
2.00
-20°C
10.91
4.91
2.22
-15°C
13.15
5.14
2.56
-10°C
15.38
5.36
2.87
-7°C
16.72
5.50
3.04
-5°C
17.62
5.59
3.15
0°C
19.85
5.81
3.42
5°C
22.43
5.84
3.84
7°C
23.46
5.85
4.01
10°C
25.00
5.87
4.26
15°C
25.77
5.46
4.72
20°C
26.54
5.04
5.27
25°C
26.82
5.02
5.34
30°C
28.22
4.97
5.68
35°C
29.61
4.92
6.02
NOTE: The values of heating capacity/input power/COP are based on measurement of EN14511 standard:
• FT < 45°C: The flow rate obtained during the test at the standard rating conditions of OT 7°C and Water temp. flow/return 35°C / 30°C, 2,773 l/h
• FT ≥ 45°C: The flow rate obtained during the test at the standard rating conditions of OT 7°C and Water temp. flow/return 45°C / 30°C, 2,653 l/h
• FT ≥ 55°C: The flow rate obtained during the test at the standard rating conditions of OT 7°C and Water temp. flow/return 55°C / 30°C, 1,583 l/h
7-1. Model: WOYG160LJL
35°C
40°C
HC
IP
COP
HC
IP
COP
8.37
4.58
1.83
8.55
5.07
1.69
10.73
5.24
2.05
10.55
5.58
1.89
12.76
5.41
2.36
12.35
5.69
2.17
14.80
5.58
2.65
14.16
5.81
2.44
16.01
5.68
2.82
15.24
5.87
2.60
16.83
5.75
2.93
15.96
5.92
2.70
18.86
5.92
3.19
17.76
6.03
2.95
21.31
5.95
3.58
19.93
6.00
3.32
22.93
5.98
3.83
20.79
5.99
3.47
23.75
5.98
3.97
22.09
5.97
3.70
24.40
5.51
4.43
22.55
5.51
4.09
25.05
5.04
4.97
23.01
5.04
4.57
25.19
4.99
5.05
23.20
4.93
4.71
26.48
4.96
5.34
24.56
4.93
4.98
27.76
4.92
5.64
25.92
4.92
5.27
45°C
50°C
HC
IP
COP
HC
IP
8.74
5.56
1.57
8.61
5.93
10.37
5.91
1.75
9.91
6.01
11.92
5.97
2.00
11.24
6.04
13.47
6.03
2.23
12.58
6.06
14.39
6.06
2.37
13.37
6.08
15.01
6.08
2.47
13.91
6.09
16.56
6.14
2.70
15.24
6.11
18.51
6.05
3.06
16.86
6.03
19.28
6.01
3.21
17.50
5.99
20.45
5.95
3.44
18.47
5.94
20.44
5.47
3.74
17.88
5.44
20.42
4.99
4.09
17.28
4.93
20.84
4.92
4.24
18.11
4.91
22.46
4.92
4.57
18.64
4.91
24.07
4.92
4.89
19.16
4.90
- (01-16) -
55°C
60°C
COP
HC
IP
COP
HC
IP
1.45
1.65
9.06
6.11
1.48
7.95
6.13
1.86
10.25
6.10
1.68
9.00
6.04
2.08
11.43
6.10
1.87
10.13
6.03
2.20
12.14
6.09
1.99
10.80
6.03
2.28
12.62
6.09
2.07
11.24
6.04
2.49
13.80
6.08
2.27
12.35
6.08
2.80
14.99
6.01
2.49
13.37
6.01
2.92
15.46
5.98
2.59
13.78
5.98
3.11
16.17
5.93
2.73
14.39
5.93
3.29
16.18
5.41
2.99
14.11
5.36
3.51
16.18
4.88
3.32
13.83
4.78
3.69
15.02
4.90
3.07
13.62
4.88
3.80
15.47
4.89
3.16
13.97
4.88
3.91
15.91
4.87
3.27
14.31
4.88
7. Heating capacity table
COP
1.30
1.49
1.68
1.79
1.86
2.03
2.22
2.30
2.43
2.63
2.89
2.79
2.86
2.93

Advertisement

Table of Contents
loading

  Related Manuals for Fujitsu Super High Power Series

This manual is also suitable for:

Wsyg160dj6Wsyk170dj9Woyg160ljlWoyk150ljlWoyk170ljl