Maintenance

WARNING:
Brewer should be unplugged from
electrical outlet before any service is performed.
ADJUSTMENTS TO BE PERFORMED BY QUALIFIED
SERVICE PERSONNEL ONLY.
The water flow rate coming from the hot water tank is
constant/fixed at 0.75 gal/min. Increasing or decreasing
the amount of hot water dispensed from tank can be
used to adjust the strength of the tea.
The Longer water flows - More water - Weaker tea; Less
water flows - Less water - Stronger tea.
The TB3 Brewer will complete a full cycle in
approximately 5 to 10 min.
BREW TIMER ADJUSTMENT (mounted inside top
housing)
Controls the brewing time (min.) for brewing Coffee
and Hot Tea Concentrate.
The brewing time, temperature, and amount of product
used in the funnel affects the drink strength. See Flavor
Chart of Tea Flavors and Grams to be used.
Factory set at 3 min. for brewing 3 liters [3/4 gal.] of Tea
Concentrate [later to be diluted with 2 1/4 gal. of cold
water which makes up the total 3 gal. Iced Tea].
• To increase or decrease dispensing time and
volume of hot water dispensed, turn knob in the
direction shown on timer.
• To reset brewer to factory settings:
1. Push the Brew Button (HOT TEA), and then adjust
Timer to 3 min.
2. Adjust the Dispense Valve 1/4 turn at a time, if
necessary, to increase or decrease the Hot Water
Flow.
3. Push the Brew Button (ICED TEA), and then adjust
the Timer to 3 to 5 min. depending on the water
pressure in the main water line.
6
COLD WATER DILUTION
DELAY TIMER ADJUSTMENT (located inside the unit,
near the water inlet valve).
Set Delay Timer knob approximately as shown in
diagram. This setting corresponds to a delay time of 1.5
minutes after the hot tea begins to dispense. If the
water pressure requires a different setting on the Cold
Water Timer, then the Delay Timer also needs to be
adjusted so that it delays the Cold Water 1.5 minutes
after the hot tea begins to dispense.
SPECIAL ORDER
This setting corresponds to a delay time of 5 minutes
after the hot tea finishes dispensing.
If the water pressure is higher than 20 PSI, decrease the
setting on the Cold Water Timer and Delay Timer.
If the water pressure is lower than 20 PSI, increase only
the setting on the Cold Water Timer to Max.
WARNING:
electrical outlet before any service is performed.
DUAL WATER INLET VALVE:
The Water Inlet Valve is located on the lower part of
the main body with the threaded end protruding out
of the back.
The Water Inlet Valve allows water flow up to 0.87
gal./min. [gpm].
One side supplies water to the tank and one side
supplies water directly to the Iced Tea dilution water
nozzle. The time that each side draws water is
controlled by the Hot Water Timer and Cold Water
Timer.