  • Page 1 GIANT 2 UL O P E R A T O R ’ S M A N U A L...
  • Page 3: Installation

    1 TECHNICAL CHARACTERISTICS Transparent removable bowls Capacity of each bowl, approx. Dimensions: width depth height Net weight, approx. Gross weight, approx. Adjustable thermostats Hermetic compressor Air-cooled condenser Overload protector Safety pressure switch Noise level lower than 70 dB (A) IMPORTANT Read electrical ratings written on the data plate of the individual units;...
  • Page 4: Operating Procedures

    5 OPERATING PROCEDURES ATTENTION In case of damages, the power cord must be replaced by qualified personnel only in order to prevent any shock hazard. 1 - Clean and sanitize the unit according to the instructions in t h i s m a n u a l . S e e c h a p t e r 5 . 3 C L E A N I N G A N D SANITIZING PROCEDURES.
  • Page 5: Description Of Controls

    fixing button, push it and lift the cover. (see figure 3) figure 3 5. 1 DESCRIPTION OF CONTROLS The dispenser is equipped with a power switch and a light switch. In addition each bowl is individually operated by a mixer/refrigeration switch. In fact it is possible to dispense both soft drinks and Granita.
  • Page 6: Cleaning And Sanitizing Procedures

    duct (the indicator F will go up in opening G). figure 6 2 - Beverage temperature adjustment: proper beverage temperature is factory preset. To reset, turn the knob located in each switch box as follows: - towards right (clockwise) to decrease temperature. - towards left (counterclockwise) to increase temperature.
  • Page 7 figure 9 3 - Slide the outer spiral out (see figure 10) and then the inside auger (see figure 11). figure 10 figure 11 4 - Remove the bowl gasket from its seat (see figure 12). figure 12 5 - Remove the faucet assembly sliding the pin and pulling up Ugolini S.p.A.
  • Page 8: In-Place Sanitization

    3 - Do not immerse the lighted top covers in liquid. Wash them apart with the cleaning solution. Carefully clean their undersides. 4 - In the same manner clean the evaporator cylinder(s) using a soft bristle brush. 5 - Rinse all cleaned parts with cool clean water. 5.
  • Page 9: Routine Maintenance

    addition to the Disassembled Parts Sanitization described before, but never in lieu of it. 1 - Prepare two gallons of a warm (45-60°C, 120-140 °F) s a ni t iz i n g s o l u t i o n ( 1 0 0 P P M a v a i la b l e c h l o r i n e concentration or 1 spoon of sodium hypoclorite diluted with 2 liters of water) according to your local Health Codes and manufacturer’s specifications.