Temperature Violation Detected - System Shutting Down In X Seconds - HP DL360 Reference And Troubleshooting Manual

Whp wireless server user manual
Hide thumbs Also See for DL360:
Table of Contents

Advertisement

196
HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
Temperature violation detected - system Shutting Down in x
seconds
Audible Beeps: 1 long, 1 short
Possible Cause: The system has reached a cautionary temperature level and is
shutting down in X seconds.
Action: Adjust the ambient temperature, install fans, or replace any failed fans.
Unsupported Processor Detected System will ONLY boot ROMPAQ
Utility. System Halted.
Audible Beeps: 1 long, 1 short
Possible Cause: Processor and/or processor stepping is not supported by the
current system ROM.
Action: Refer to the server documentation for supported processors. If a ROM
version exists that supports the processor, insert a Systems ROMPAQ diskette
with the latest ROM version and flash the system to the latest ROM version.
WARNING: A Type 2 Header PCI Device Has Been Detected...
The BIOS will not configure this card.
It must be configured properly by the OS or driver.
Audible Beeps: 2 short
Possible Cause: Only Type 0 and Type 1 Header PCI Devices are configured by
the system ROM. The device will not work unless the OS or device driver
properly configure the card. Typically this message only occurs when PCI cards
with a PCI to PCMCIA bridge are installed.
Action: Refer to the operating system documentation or the device driver
information that ships with the Type 2 PCI device.