Adapter/Nvram Id Mismatch; Array Accelerator Battery Pack X Not Fully Charged; Array Accelerator Battery Pack X Below Reference Voltage (Recharging); Board In Use By Expand Operation - HP DL360 Reference And Troubleshooting Manual

Whp wireless server user manual
Hide thumbs Also See for DL360:
Table of Contents

Advertisement

Adapter/NVRAM ID Mismatch

Description: EISA NVRAM has an ID for a different controller from the one
physically present in the slot.
Action: Run the server setup utility.

Array Accelerator Battery Pack X not Fully Charged

Description: Battery is not fully charged.
Action: If 75% of the batteries present are fully charged, the array accelerator is
fully operational. If more than 75% of the batteries are not fully charged, allow
36 hours to recharge them.

Array Accelerator Battery Pack X Below Reference Voltage (Recharging)

Description: Battery pack on the array accelerator is below the required voltage
levels.
Action: Replace the array accelerator board if the batteries do not recharge
within 36 powered-on hours.

Board in Use by Expand Operation

Description: Array accelerator memory is in use by an expand operation.
Action: Operate the system without the array accelerator board until the expand
operation completes.

Board not Attached

Description: An array controller is configured for use with array accelerator
board, but one is not connected.
Action: Connect array accelerator board to array controller.