Download Print this page
Halma LZR-WIDESCAN Manual

Halma LZR-WIDESCAN Manual

Opening, presence & safety sensor for industrial doors
Hide thumbs Also See for LZR-WIDESCAN:

Advertisement

Quick Links

LZR
OPENING, PRESENCE & SAFETY SENSOR
FOR INDUSTRIAL DOORS
Visit website for
available languages of
this document.
75.5916.06 LZR-WIDESCAN 20200625
-WIDESCAN
®
Page 1 of 20

Advertisement

loading

Summary of Contents for Halma LZR-WIDESCAN

  • Page 1 -WIDESCAN ® OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS Visit website for available languages of this document. 75.5916.06 LZR-WIDESCAN 20200625 Page 1 of 20...
  • Page 2 12. parallel angle adjustment screw (2) cover lock 13. lateral angle lock screw (1) cable passage 14. mounting bracket USER’S GUIDE SYMBOLS Factory value (User’s Guide) Factory value (LCD) Important! Good to know Page 2 of 20 75.5916.06 LZR-WIDESCAN 20200625...
  • Page 3 75.5916.06 LZR-WIDESCAN 20200625 Page 3 of 20...
  • Page 4 Speed: detection of object with a minimum speed Height: detection of object with a minimum height The sensor carries out a 3D object analysis and detects depending on height, width, depth, direction, and speed. Page 4 of 20 75.5916.06 LZR-WIDESCAN 20200625...
  • Page 5 Position the sensor horizontally (as shown) and Plug in the connector and pass the cable (PN secure the sensor to the mounting bracket. 35.1554) through the cable passage without making a loop. 75.5916.06 LZR-WIDESCAN 20200625 Page 5 of 20...
  • Page 6 NOTE: It is best to make minor adjustments to the sensor and then verify that you are not obstructing the pattern. Verify that both red spots are on the floor with no interference. Page 6 of 20 75.5916.06 LZR-WIDESCAN 20200625...
  • Page 7 Presence detection Troubleshooting Safety detection SETTINGS All fields Presence field Setting any field width or depth to Motion field Safety field 000 will eliminate that field along with its associated LED flash. Pull-cord 75.5916.06 LZR-WIDESCAN 20200625 Page 7 of 20...
  • Page 8 ASSIGN OUTPUT FUNCTIONS, OUTPUT LOGIC, AND HOLD TIMES • using the LCD (BEA recommends), locate the IN-OUT menu and set desired parameters reference the LZR-WIDESCAN MENU TREE (75.5982) • using the remote control – see page 9 c. PROGRAM FIELD SETTINGS Program all desired field settings according to pages 10 –...
  • Page 9 Factory Reset full partial partial: reset of all values except IN/OUT Red Spots Pressing "magic wand" twice activates the 2 visible laser spots, enabling angle adjustments and sensor positioning. 75.5916.06 LZR-WIDESCAN 20200625 Page 9 of 20...
  • Page 10 – approaching with cross traffic rejection UNI 100%+ +1m in front of door : bidirectional detection without cross traffic rejection unidirectional detection – approaching in any direction (distance between object and sensor decreases) Immunity Page 10 of 20 75.5916.06 LZR-WIDESCAN 20200625...
  • Page 11 5 min 10 min 30 min 60 min 120 min infinite (for objects < 1’6") Immunity Uncovered Zone 2" 4" 6" 8" An object smaller than the chosen F2 value is not detected. 75.5916.06 LZR-WIDESCAN 20200625 Page 11 of 20...
  • Page 12 See the menu path below to access heating values: The sensor draws considerably more power with the heating function ON. Reference the MAIN  QUICK START  >MORE  OFF (default) Technical Specifications to ensure you have enough available power. AUTO Page 12 of 20 75.5916.06 LZR-WIDESCAN 20200625...
  • Page 13 5 CLOSING THE SENSOR Lock the sensor position by firmly Reclip the sensor cover horizontally Lock the cover by turning the fastening the angle lock screw. and close it as indicated. lock screw clockwise. 75.5916.06 LZR-WIDESCAN 20200625 Page 13 of 20...
  • Page 14: Troubleshooting

    1 minute. Motion detection starts Negative angle is too large Reduce angle of the sensor. too late Can’t find your answer? Visit BEAsensors.com or scan QR code for Frequently Asked Questions! Page 14 of 20 75.5916.06 LZR-WIDESCAN 20200625...
  • Page 15 – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107). Verify that all appropriate industry signage and warning labels are in place. Tech Support & Customer Service: 1-800-523-2462 General Tech Questions: techservices-us@BEAsensors.com | Tech Docs: www.BEAsensors.com 75.5916.06 LZR-WIDESCAN 20200625 Page 15 of 20...
  • Page 16 APPENDIX Page 16 of 20 75.5916.06 LZR-WIDESCAN 20200625...
  • Page 17 To quickly send an overview of all selected values, scan the QR code on the LCD screen using a smartphone scanner app. If needed, use the flashlight of your phone to improve contrast. A string of digits will appear on your phone. Send this string via email to our technical support team. 75.5916.06 LZR-WIDESCAN 20200625 Page 17 of 20...
  • Page 18 Always verify the detection area 40cm 30 30 40cm after changing this parameter. Without selecting a color key, all 3 detection field widths (motion, presence, and safety) are adjusted at the same time. Page 18 of 20 75.5916.06 LZR-WIDESCAN 20200625...
  • Page 19 30 or 120 sec via Quick Start > More > TeachInDelay). The delay by remote control is 5 seconds. DO NOT MOVE The sensor learns its background as long as the LED flashes red-green. continued on next page... 75.5916.06 LZR-WIDESCAN 20200625 Page 19 of 20...
  • Page 20 Always verify the field dimensions via the Field Display option on the LCD screen (Diagnostics > FieldDisplay). To delete a trace, simply relaunch a walk teach-in and clear the respective detection zone for 15 seconds. Page 20 of 20 75.5916.06 LZR-WIDESCAN 20200625...