Location
LOCATION
• Do not install on an exterior wall.
• Do not install behind a door.
• Do not install in areas with direct heat source.
• Do not install near any air discharge grill.
• Do not install in areas exposed to direct sunlight.
• Ensure Room Controller has sufficient natural air circulation.
• Ensure wall surface is flat and clean.
• Ensure external thermal sensor wirings are away from noisy electrical sources.
• Install 1.3 to 1.5 meter (52 to 60 inches) above the floor.
• Perform preventive maintenance on the damper and Variable Air Volume (VAV) box, according to the supplier documentation.
Failure to follow these instructions can result in equipment damage.
Cleaning the Room Controller
CLEANING THE ROOM CONTROLLER
• Use a soft, pre-moistened lint-free cloth for cleaning.
• Avoid getting moisture in openings.
• Do not spray anything directly on the Room Controller or use compressed air.
• Do not use caustic/corrosive products, ammonia, solvents or any cleaning product containing alcohol or grit.
• Never use tools directly on the touchscreen.
• Never use paint on the Room Controller.
• Do not drop or crush the Room Controller, or allow it to come into contact with liquids.
• Do not use a damaged device (such as one with a cracked screen).
Failure to comply with these recommendations will result in damage to the unit and void the manufacturer's warranty.

OVERVIEW

The acccessory covers with embedded Passive Infra-Red (PIR) motion detector have been specifically designed to work with all
compatible VT7000 Series Room Controllers. Any Room Controller compatible with VI-PIR covers use the VT7xxxxX5xxx(X)
assignment. The 5 identifies the Room Controller base has the necessary onboard polarized PIR connector and functionality
added.
When equipped with a PIR cover, a VT7000 series Room Controoler provides advanced active occupancy logic, which
automatically switches occupancy levels from Occupied to Stand-By, as well as Unoccupied as required by local activity being
present or not.
Models Available
The below table shows which PIR covers are compatible for which model.
PIR COVER PART NUMBER
COV-PIR-FCU-C-5000
COV-PIR-FCU-L-5000
COV-PIR-RTU-5000
COV-PIR-ZN-5000
Instalation Tips
TIP
General Installation
General Installation
Initial Power Up & Commissioning
Initial Power Up & Commissioning
Viconics Technologies Inc. | 7262 Marconi Street, Montreal, Quebec, Canada H2R 2Z5 | Tel: (514) 313-8885 | Toll free: 1 (800) 563-5660
028-0184-05-PIR-Cover-Installation-Guide_A4_EN
NOTICE
NOTICE
DESCRIPTION
PIR cover with Commercial FCU interface
PIR cover with Hotel/Lodging interface
PIR cover for roof-top thermostats
PIR cover for zoning thermostats
DESCRIPTION
PIR Connector
Security Screw
PIR warm-up period
Visual indication (status of PIR)
www.viconics.com | sales@viconics.com
COMPATIBLE MODEL
VT73x0X5x00(X)
VT73x5X5x00(X)
VT76xxX5x00(X)
VT7200X5x00(X)
EXPLANATION
Polarized connector is located at bottom left hand corner of
Room Controller
A security screw is provided in the shipping box. This screw
should be carefully installed in the intended mounting
position located at bottom center of cover.
PIR Sensor may take up to 60 seconds after initial warm-up
period to detect movement consistent with typical detection
pattern.
Visual indication of PIR activity for commissioning shows via
blinking LEDs located on the cover under the PIR lens. LEDs
stay active while occupant is in field of detection pattern for a
period of 30 minutes after initial power up.