• The device must be connected by a skilled qualified person.
• Device of protection class III.
• Electric supply via SELV circuits only.
• Disconnect power before connecting the device.
• The IP rating indicated in the data sheet is only guaranteed if the M12
connectors are firmly screwed.
• The device can be damaged by insufficiently tightened M12 connectors.
• Screw the M12 connector to the device applying 1 to 1.5 Nm.
Connect the
BLUEBOX
CAN bus connection cable.
Pin
No
PE
1
+ PWR
2
- PWR
3
CAN H
4
CAN L
5
SHIELD
-
B5U033000E
5
Electrical Connections
5.1
Item 5227U
to the voltage supply and CAN bus using a suitable M12
5-poles M12 A-coded male connector
Min
Typical
10Vdc
12/24Vdc
Max
Protected Earth
36Vdc
DC power supply
DC power supply return path
CAN bus connection (CAN H)
CAN connection (CAN L)
Protected Earth
Description