iDTRONIC BLUEBOX ADVANT UHF Manual page 31

M30 form factor uhf rfid system
Table of Contents

Advertisement

Value Definition:
Sub-index 00h contains the number of valid object entries within the record. The
number of valid objects entries shall be the number of the general configuration
parameters. Its value is 03h.
Sub-index 01h to 03h contains a configuration parameter. An attempt to change
the value of the configuration parameter to any not supported value shall be
responded with the SDO abort transfer service (abort code: 06090030h). See
the
BLUEBOX
user manual for value definition details.
Parameter
Description
How
'continuous' mode.
Mode
only after a reboot of the reader.
The power step in dynamic power management
mode activated.
Power Step
only after a reboot of the reader.
The time step in dynamic power management
mode activated.
Time Step
only after a reboot of the reader.
Sub-Index
Parameter
01h
02h
Power Step
03h
Time Step
Object Descritpion:
Index
Name
B5U033000E
the
reader
manages
Note that this parameter become effective
Note that this parameter become effective
Note that this parameter become effective
Description
How the reader manages the power in 'continuous' mode:
0x00: Off;
0x01: Up, only increase power by power step every time
Mode
step;
0x02: Up / Down, increase power and then decrease it by
power step every time step.
The power step in dynamic power management mode activated:
0x01 ... 0x05 for power step in dB (1 ... 5 dB);
0x81 ... 0xB2 for power step in mW x 10 (10 ... 500 mW).
The time step in dynamic power management mode activated:
Decimal 1 ... 99 for time in ms x 100 (0.1 ... 9.9 seconds).
2203h
Dynamic power configuration
the
power
in
10 ... 500 mW
0.1 ... 9.9
Range
Default
Off
Up
Off
Up/down
1 ... 5 dB
1 dB
1.0 sec
seconds
Page 31 of 54