DANGER
Electrical Shock
• Turn off all electrical supply to the disposer before attempt-
ing any work on it. Use a voltmeter or circuit tester to
ensure power is off.
• Installation must conform to all local electrical codes.
• All control centers and disposers must be carefully and
permanently grounded.
• A properly fused disconnect must be installed at the electri-
cal supply source for the control center.

MANUAL STARTING SWITCHES

Manual Starting (On/Off) Switch
All voltages.
Do not use L3 and T3 for single phase applications.
Manual Starting (On/Off) Switch -
With Pressure Switch
All voltages 1/2 HP thru 5 HP.
Do not use L3 and T3 for single phase applications.
Wiring Diagrams
• Ensure that the control center voltage and phase match
the disposer motor and electrical supply. Check name-
plates on disposers and control centers for voltage and
phase specification.
• The disposer motor wiring connection is shown in the
disposer terminal box.
Manual Starting (On/Off) Switch -
With Time Delay Relay
All voltages except 460 volts.
Do not use L3 and T3 for single phase applications.
11
Property Damage
See standard motor connection wiring
diagram in motor terminal box.